Literature DB >> 20024028

A blood sampling microsystem for pharmacokinetic applications: design, fabrication, and initial results.

Tao Li1, Adam Barnett, Karen L Rogers, Yogesh B Gianchandani.   

Abstract

This paper describes a microsystem for automated blood sampling from laboratory mice used in pharmacokinetic studies. Intended to be mounted as a "backpack" on a mouse, it uses a microneedle, reservoir, and an actuator to instantaneously prick the animal for a time-point sample, eliminating the need for a tethered catheter with large dead volume. The blood is collected by capillary effect through a 31-33 gauge microneedle (250-210 microm OD) into a approximately 1 microL micromachined steel reservoir. The voice coil actuator provides a peak force of approximately 300 mN, which amply exceeds the measured piercing force of mouse skin (i.e., 60-85 mN for a 31-gauge needle with 12 degrees bevel). The sampling system was tested in vitro using a mock vessel with adjustable pressure; the reservoir was filled in <0.15 s by a combination of the capillary effect and blood pressure. The system may also be used to sample interstitial fluid, but the absence of blood pressure makes it necessary to enhance the capillary effect of the needle. This is accomplished by either electropolishing the inner surface to make it more hydrophilic or using a polymer wire insert to increase the surface area. The steel surface of the reservoir is also coated with silicon oxynitride by plasma-enhanced chemical vapor deposition to improve its hydrophilicity. Blood from fresh bovine tissue was collected into the reservoir to simulate interstitial fluid sampling. In vivo tests on live, anesthetized mice resulted in successful collection of blood into the reservoir. The possible integration of the device in microanalytical systems and the device scalability for multisampling are discussed.

Entities:  

Mesh:

Year:  2009        PMID: 20024028     DOI: 10.1039/b910508e

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  9 in total

1.  Type, duration, and incidence of pathologic findings after retroorbital bleeding of mice by experienced and novice personnel.

Authors:  Joanna H Fried; David B Worth; Angela K Brice; F Claire Hankenson
Journal:  J Am Assoc Lab Anim Sci       Date:  2015-05       Impact factor: 1.232

2.  An Automated Mouse Tail Vascular Access System by Vision and Pressure Feedback.

Authors:  Yen-Chi Chang; Brittany Berry-Pusey; Rashid Yasin; Nam Vu; Brandon Maraglia; Arion X Chatziioannou; Tsu-Chin Tsao
Journal:  IEEE ASME Trans Mechatron       Date:  2014-10-16       Impact factor: 5.303

Review 3.  Microneedles for transdermal diagnostics: Recent advances and new horizons.

Authors:  Gui-Shi Liu; Yifei Kong; Yensheng Wang; Yunhan Luo; Xudong Fan; Xi Xie; Bo-Ru Yang; Mei X Wu
Journal:  Biomaterials       Date:  2019-12-26       Impact factor: 12.479

4.  Polymer-based disposable microneedle array with insertion assisted by vibrating motion.

Authors:  F-W Lee; W-H Hung; C-W Ma; Y-J Yang
Journal:  Biomicrofluidics       Date:  2016-01-19       Impact factor: 2.800

5.  Pharmacogenetics in clinical pediatrics: challenges and strategies.

Authors:  Sara L Van Driest; Tracy L McGregor
Journal:  Per Med       Date:  2013-09       Impact factor: 2.512

6.  Counting-based microfluidic paper-based devices capable of analyzing submicroliter sample volumes.

Authors:  Md Almostasim Mahmud; Eric J M Blondeel; Brendan D MacDonald
Journal:  Biomicrofluidics       Date:  2020-01-10       Impact factor: 2.800

Review 7.  Microneedles for drug and vaccine delivery.

Authors:  Yeu-Chun Kim; Jung-Hwan Park; Mark R Prausnitz
Journal:  Adv Drug Deliv Rev       Date:  2012-05-01       Impact factor: 15.470

8.  Hydrogel Microfilaments toward Intradermal Health Monitoring.

Authors:  Nalin Tejavibulya; David A M Colburn; Francis A Marcogliese; Kyung-Ae Yang; Vincent Guo; Shilpika Chowdhury; Milan N Stojanovic; Samuel K Sia
Journal:  iScience       Date:  2019-10-23

Review 9.  Lab on a chip for in situ diagnosis: From blood to point of care.

Authors:  Jaewon Lee; Sang-Hoon Lee
Journal:  Biomed Eng Lett       Date:  2013-08-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.