Literature DB >> 20023326

Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I'mRT MatriXX--a feasibility study.

Barbara Dobler1, Natalia Streck, Elisabeth Klein, Rainer Loeschel, Petra Haertl, Oliver Koelbl.   

Abstract

The 2D ionization chamber array I'mRT MatriXX (IBA, Schwarzenbruck, Germany) has been developed for absolute 2D dosimetry and verification of intensity-modulated radiation therapy (IMRT) for perpendicular beam incidence. The aim of this study is to evaluate the applicability of I'mRT MatriXX for oblique beam incidence and hybrid plan verification of IMRT with original gantry angles. For the assessment of angular dependence, open fields with gantry angles in steps of 10 degrees were calculated on a CT scan of I'mRT MatriXX. For hybrid plan verification, 17 clinical IMRT plans and one rotational plan were used. Calculations were performed with pencil beam (PB), collapsed cone (CC) and Monte Carlo (MC) methods, which had been previously validated. Measurements were conducted on an Elekta SynergyS linear accelerator. To assess the potential and limitations of the system, gamma evaluation was performed with different dose tolerances and distances to agreement. Hybrid plan verification passed the gamma test with 4% dose tolerance and 3 mm distance to agreement in all cases, in 82-88% of the cases for tolerances of 3%/3 mm, and in 59-76% of the cases if 3%/2 mm were used. Separate evaluation of the low dose and high dose regions showed that I'mRT MatriXX can be used for hybrid plan verification of IMRT plans within 3% dose tolerance and 3 mm distance to agreement with a relaxed dose tolerance of 4% in the low dose region outside the multileaf collimator (MLC).

Entities:  

Mesh:

Year:  2009        PMID: 20023326     DOI: 10.1088/0031-9155/55/2/N02

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Second Cancer Risk after simultaneous integrated boost radiation therapy of right sided breast cancer with and without flattening filter.

Authors:  Barbara Dobler; Johannes Maier; Bernadette Knott; Manuel Maerz; Rainer Loeschel; Oliver Koelbl
Journal:  Strahlenther Onkol       Date:  2016-08-17       Impact factor: 3.621

2.  Evaluation of volumetric modulated arc therapy (VMAT) with Oncentra MasterPlan® for the treatment of head and neck cancer.

Authors:  Judith Alvarez-Moret; Fabian Pohl; Oliver Koelbl; Barbara Dobler
Journal:  Radiat Oncol       Date:  2010-11-22       Impact factor: 3.481

3.  Cherenkov imaging for total skin electron therapy (TSET).

Authors:  Yunhe Xie; Heather Petroccia; Amit Maity; Tianshun Miao; Yihua Zhu; Petr Bruza; Brian W Pogue; John P Plastaras; Lei Dong; Timothy C Zhu
Journal:  Med Phys       Date:  2019-11-26       Impact factor: 4.071

4.  Searching standard parameters for volumetric modulated arc therapy (VMAT) of prostate cancer.

Authors:  Marius Treutwein; Matthias Hipp; Oliver Koelbl; Barbara Dobler
Journal:  Radiat Oncol       Date:  2012-07-11       Impact factor: 3.481

5.  Quality assurance of TomoDirect treatment plans using I'mRT MatriXX.

Authors:  Cw Kong; Sk Yu; Ky Cheung; H Geng; Yw Ho; Ww Lam; Wk Wong
Journal:  Biomed Imaging Interv J       Date:  2012-04-01

6.  A planning study for palliative spine treatment using StatRT and megavoltage CT simulation.

Authors:  Yi Rong; Poonam Yadav; Bhudatt Paliwal; Lu Shang; James S Welsh
Journal:  J Appl Clin Med Phys       Date:  2010-10-30       Impact factor: 2.102

7.  Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study.

Authors:  Johannes Maier; Bernadette Knott; Manuel Maerz; Rainer Loeschel; Oliver Koelbl; Barbara Dobler
Journal:  Radiat Oncol       Date:  2016-08-31       Impact factor: 3.481

8.  Re-irradiating spinal column metastases using IMRT and VMAT with and without flattening filter - a treatment planning study.

Authors:  Barbara Dobler; Amine Khemissi; Tina Obermeier; Matthias G Hautmann; Zaira Katsilieri; Oliver Kölbl
Journal:  Radiat Oncol       Date:  2016-03-01       Impact factor: 3.481

9.  Angular dependence correction of MatriXX and its application to composite dose verification.

Authors:  Yoshinobu Shimohigashi; Fujio Araki; Hirofumi Tominaga; Junichi Sakata; Keiichi Kawasaki; Nagisa Kanetake; Yuki Iwashita; Saori Yoshimura; Tamami Kawakami; Terunobu Ishihara; Tomoko Okuda; Kasei Kogo
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

10.  Volumetric-modulated arc therapy and intensity-modulated radiation therapy treatment planning for prostate cancer with flattened beam and flattening filter free linear accelerators.

Authors:  Marius Treutwein; Matthias Hipp; Oliver Koelbl; Barbara Dobler
Journal:  J Appl Clin Med Phys       Date:  2017-08-30       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.