Literature DB >> 20022879

Gold-coated pacemaker implantation after allergic reactions to pacemaker compounds.

Thomas Syburra1, Ulrich Schurr, Mariette Rahn, Kirk Graves, Michele Genoni.   

Abstract

An 86-year-old man underwent pacemaker implantation for symptomatic atrio-ventricular block grade 2 Mobitz II. The patient suffered repeated admissions for iterative sterile wound necrosis, leading to two generator re-implantations. No bacterial infection was detected in the microbiological screening tests. The skin patch testing to titanium was negative. Nevertheless, we decided to remove the pacemaker system and to implant a gold-plated generator with polyurethane leads. Since then, there has been no recurrence of wound complications. Gold-plated generator and polyurethane leads are effective in treating allergic reactions to pacemaker system components in selected cases. Negative skin patch testing to titanium does not exclude allergic reaction to this pacemaker component.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20022879     DOI: 10.1093/europace/eup411

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  7 in total

1.  Cardiac rhythm device contact dermatitis.

Authors:  Jaskaran Kang; Christopher S Simpson; Debra Campbell; Rozita Borici-Mazi; Damian P Redfearn; Kevin A Michael; Hoshiar Abdollah; Adrian Baranchuk
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-08-13       Impact factor: 1.468

2.  Blood Plasma Stabilized Gold Nanoclusters for Personalized Tumor Theranostics.

Authors:  Greta Jarockyte; Vilius Poderys; Virginijus Barzda; Vitalijus Karabanovas; Ricardas Rotomskis
Journal:  Cancers (Basel)       Date:  2022-04-08       Impact factor: 6.575

3.  Extraction of chronically implanted cardiovascular electronic device leads.

Authors:  Jeffrey Brinker
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-08

4.  Gold-coated pacemaker implantation for a patient with type IV allergy to titanium.

Authors:  Alexander Kypta; Hermann Blessberger; Michael Lichtenauer; Thomas Lambert; Juergen Kammler; Clemens Steinwender
Journal:  Indian Pacing Electrophysiol J       Date:  2016-02-23

5.  Allergic reaction to pacemaker compounds: Case reports.

Authors:  Rogelio Robledo-Nolasco; Luis Gerardo González-Barrera; Jesús Díaz-Davalos; Gerardo De León-Larios; Margarito Morales-Cruz; David Ramírez-Cedillo
Journal:  HeartRhythm Case Rep       Date:  2022-03-10

6.  A Rare Case of Recurrent Pacemaker Allergic Reaction.

Authors:  Muhammed Shittu; Pooja Shah; Walid Elkhalili; Addi Suleiman; Hamid Shaaban; Pradip A Shah; Fayez Shamoon
Journal:  Heart Views       Date:  2015 Apr-Jun

7.  Towards unambiguous reporting of complications related to deep brain stimulation surgery: A retrospective single-center analysis and systematic review of the literature.

Authors:  Katja Engel; Torge Huckhagel; Alessandro Gulberti; Monika Pötter-Nerger; Eik Vettorazzi; Ute Hidding; Chi-Un Choe; Simone Zittel; Hanna Braaß; Peter Ludewig; Miriam Schaper; Kara Krajewski; Christian Oehlwein; Katrin Mittmann; Andreas K Engel; Christian Gerloff; Manfred Westphal; Christian K E Moll; Carsten Buhmann; Johannes A Köppen; Wolfgang Hamel
Journal:  PLoS One       Date:  2018-08-02       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.