Literature DB >> 20022485

The evolution of real-time PCR machines to real-time PCR chips.

Dasheng Lee1, Pei-Jer Chen, Gwo-Bin Lee.   

Abstract

Development of Micro-Electro-Mechanical Systems (MEMS) technology has recently allowed the migration of real-time polymerase chain reaction (PCR) machines to lab-on-a-chip systems. The miniaturization of biological instruments has been studied extensively, with several prototypes constructed and tested. In this study, the lab-on-a-chip system is evaluated; its DNA quantification is estimated by theorems, and the specifications of proposed chip prototypes are compared with the original machines. The analysis results suggest five hypotheses. Using experiments and the data collected from published papers, these hypotheses were either verified or rejected, and the advantages and shortcomings of real-time PCR chips were identified. The proven advantages of the lab-on-a-chip system are its compact size, low sample volume to nano-liter, and short analysis time-less than 10s to complete one PCR cycle and 370 s for completing the whole quantification process. However, the detection limits, quantification uncertainties, and melting analysis ability of the chip prototypes are at best comparable to, and perhaps worse than, those of commercial instruments. Real-time PCR chips are not perfectly accurate diagnostic tools for a laboratory but they have advantages over traditional techniques for point-of-care testing. (c) 2009 Elsevier B.V. All rights reserved.

Mesh:

Year:  2009        PMID: 20022485     DOI: 10.1016/j.bios.2009.11.021

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  Molecular markers and mechanisms of stroke: RNA studies of blood in animals and humans.

Authors:  Frank R Sharp; Glen C Jickling; Boryana Stamova; Yingfang Tian; Xinhua Zhan; DaZhi Liu; Beth Kuczynski; Christopher D Cox; Bradley P Ander
Journal:  J Cereb Blood Flow Metab       Date:  2011-04-20       Impact factor: 6.200

Review 2.  Miniaturized technology for protein and nucleic acid point-of-care testing.

Authors:  Felix Olasagasti; Juan Carlos Ruiz de Gordoa
Journal:  Transl Res       Date:  2012-03-11       Impact factor: 7.012

3.  Q3: A Compact Device for Quick, High Precision qPCR.

Authors:  Marco Cereda; Alessandro Cocci; Davide Cucchi; Lillo Raia; Danilo Pirola; Lorenzo Bruno; Pietro Ferrari; Valentina Pavanati; Giorgia Calisti; Francesco Ferrara; Alessandro P Bramanti; Marco A Bianchessi
Journal:  Sensors (Basel)       Date:  2018-08-07       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.