Literature DB >> 20011656

A general total variation minimization theorem for compressed sensing based interior tomography.

Weimin Han1, Hengyong Yu, Ge Wang.   

Abstract

Recently, in the compressed sensing framework we found that a two-dimensional interior region-of-interest (ROI) can be exactly reconstructed via the total variation minimization if the ROI is piecewise constant (Yu and Wang, 2009). Here we present a general theorem charactering a minimization property for a piecewise constant function defined on a domain in any dimension. Our major mathematical tool to prove this result is functional analysis without involving the Dirac delta function, which was heuristically used by Yu and Wang (2009).

Entities:  

Year:  2009        PMID: 20011656      PMCID: PMC2786191          DOI: 10.1155/2009/125871

Source DB:  PubMed          Journal:  Int J Biomed Imaging        ISSN: 1687-4188


  2 in total

1.  Supplemental analysis on compressed sensing based interior tomography.

Authors:  Hengyong Yu; Jiansheng Yang; Ming Jiang; Ge Wang
Journal:  Phys Med Biol       Date:  2009-08-28       Impact factor: 3.609

2.  Compressed sensing based interior tomography.

Authors:  Hengyong Yu; Ge Wang
Journal:  Phys Med Biol       Date:  2009-04-15       Impact factor: 3.609

  2 in total
  11 in total

1.  Compressive sensing-based interior tomography: preliminary clinical application.

Authors:  Hengyong Yu; Ge Wang; Jiang Hsieh; Daniel W Entrikin; Sandra Ellis; Baodong Liu; John Jeffrey Carr
Journal:  J Comput Assist Tomogr       Date:  2011 Nov-Dec       Impact factor: 1.826

2.  Supplemental analysis on compressed sensing based interior tomography.

Authors:  Hengyong Yu; Jiansheng Yang; Ming Jiang; Ge Wang
Journal:  Phys Med Biol       Date:  2009-08-28       Impact factor: 3.609

3.  Interior region-of-interest reconstruction using a small, nearly piecewise constant subregion.

Authors:  Katsuyuki Taguchi; Jingyan Xu; Somesh Srivastava; Benjamin M W Tsui; Jochen Cammin; Qiulin Tang
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

4.  High-order total variation minimization for interior SPECT.

Authors:  Jiansheng Yang; Hengyong Yu; Ming Jiang; Ge Wang
Journal:  Inverse Probl       Date:  2012-01-01       Impact factor: 2.407

5.  STABILITY OF THE INTERIOR PROBLEM FOR POLYNOMIAL REGION OF INTEREST.

Authors:  E Katsevich; A Katsevich; G Wang
Journal:  Inverse Probl       Date:  2012       Impact factor: 2.407

6.  Statistical interior tomography.

Authors:  Qiong Xu; Xuanqin Mou; Ge Wang; Jered Sieren; Eric A Hoffman; Hengyong Yu
Journal:  IEEE Trans Med Imaging       Date:  2011-01-13       Impact factor: 10.048

7.  Image reconstruction from limited angle projections collected by multisource interior x-ray imaging systems.

Authors:  Baodong Liu; Ge Wang; Erik L Ritman; Guohua Cao; Jianping Lu; Otto Zhou; Li Zeng; Hengyong Yu
Journal:  Phys Med Biol       Date:  2011-09-09       Impact factor: 3.609

8.  Time-resolved cardiac interventional cone-beam CT reconstruction from fully truncated projections using the prior image constrained compressed sensing (PICCS) algorithm.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2012-04-05       Impact factor: 3.609

9.  High Order Total Variation Minimization for Interior Tomography.

Authors:  Jiansheng Yang; Hengyong Yu; Ming Jiang; Ge Wang
Journal:  Inverse Probl       Date:  2010-01-01       Impact factor: 2.407

Review 10.  The meaning of interior tomography.

Authors:  Ge Wang; Hengyong Yu
Journal:  Phys Med Biol       Date:  2013-08-02       Impact factor: 3.609

View more