Literature DB >> 20010452

Retinal vessel analyzer measurements of the effect of panretinal photocoagulation on the retinal arteriolar diameter in diabetic retinopathy.

Efstratios Mendrinos1, Georgios Mangioris, Domniki N Papadopoulou, André A Dosso, Constantin J Pournaras.   

Abstract

PURPOSE: The purpose of this study was to investigate the effect of panretinal photocoagulation (PRP) on the retinal arteriolar diameter in patients with diabetic retinopathy using a retinal vessel analyzer.
METHODS: Ten eyes of 6 consecutive patients with type II diabetes and severe nonproliferative or proliferative diabetic retinopathy were studied prospectively. Measurements of the retinal arteriolar diameter were performed before the first photocoagulation session and after the end of the PRP treatment.
RESULTS: Retinal arteriolar diameter before PRP was 131 +/- 15 arbitrary units and decreased to 112 +/- 14 arbitrary units after PRP (P = 0.012). There was a significant vasoconstriction of 13.8% +/- 8.3% following PRP. Mean visual acuity before and after PRP was 0.31 +/- 0.36 logarithm of the minimal angle of resolution and 0.28 +/- 0.30 logarithm of the minimal angle of resolution, respectively (P = 0.68). There was no significant change in mean arterial pressure before and after PRP (P = 0.89). There was no correlation between the visual acuity change or the number of laser burns and the percentage change in the retinal arteriolar diameter (P > 0.1).
CONCLUSION: Panretinal photocoagulation has a vasoconstrictive effect on retinal arterioles in patients with severe nonproliferative or proliferative diabetic retinopathy. These results are consistent with an autoregulatory response of the retinal circulation to increased inner retinal oxygen tension after PRP. The retinal vessel analyzer is a fast, accurate, noninvasive, online measuring system for the study of the retinal vascular response to PRP in patients with diabetic retinopathy.

Entities:  

Mesh:

Year:  2010        PMID: 20010452     DOI: 10.1097/IAE.0b013e3181bd2f79

Source DB:  PubMed          Journal:  Retina        ISSN: 0275-004X            Impact factor:   4.256


  6 in total

1.  Reliability of vessel diameter measurements with a retinal oximeter.

Authors:  Renata Blondal; Margret Kara Sturludottir; Sveinn Hakon Hardarson; Gisli Hreinn Halldorsson; Einar Stefánsson
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-04-16       Impact factor: 3.117

2.  Effect of panretinal photocoagulation on optic nerve head blood flow with OCT angiography in patients with diabetic retinopathy.

Authors:  Saher Akbar Amanat; Asad Aslam Khan; Haroon Tayyab; Sohail Sarwar
Journal:  Pak J Med Sci       Date:  2020 Jul-Aug       Impact factor: 1.088

3.  Vascular Density of Deep, Intermediate and Superficial Vascular Plexuses Are Differentially Affected by Diabetic Retinopathy Severity.

Authors:  Mohamed Ashraf; Konstantina Sampani; Allen Clermont; Omar Abu-Qamar; Jae Rhee; Paolo S Silva; Lloyd Paul Aiello; Jennifer K Sun
Journal:  Invest Ophthalmol Vis Sci       Date:  2020-08-03       Impact factor: 4.799

4.  Statistical Model of Optical Coherence Tomography Angiography Parameters That Correlate With Severity of Diabetic Retinopathy.

Authors:  Mohammed Ashraf; Peter L Nesper; Lee M Jampol; Fei Yu; Amani A Fawzi
Journal:  Invest Ophthalmol Vis Sci       Date:  2018-08-01       Impact factor: 4.799

5.  Decision Making in Proliferative Diabetic Retinopathy Treatment.

Authors:  Mary B Kansora; Raquel Goldhardt
Journal:  Curr Ophthalmol Rep       Date:  2019-02-04

Review 6.  Diabetic Macular Edema: From Old Concepts to New Therapeutic Avenues.

Authors:  Ahmad M Mansour; Jose S Pulido; J Fernando Arevalo
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2015
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.