Literature DB >> 20006073

Simultaneous spectrophotometric determination of trace amounts of uranium, thorium, and zirconium using the partial least squares method after their preconcentration by alpha-benzoin oxime modified Amberlite XAD-2000 resin.

Jahan B Ghasemi1, E Zolfonoun.   

Abstract

A new solid phase extraction method for separation and preconcentration of trace amounts of uranium, thorium, and zirconium in water samples is proposed. The procedure is based on the adsorption of U(VI), Th(IV) and Zr(IV) ions on a column of Amberlite XAD-2000 resin loaded with alpha-benzoin oxime prior to their simultaneous spectrophotometric determination with Arsenazo III using orthogonal signal correction partial least squares method. The enrichment factor for preconcentration of uranium, thorium, and zirconium was found to be 100. The detection limits for U(VI), Th(IV) and Zr(IV) were 0.50, 0.54, and 0.48microgL(-1), respectively. The precision of the method, evaluated as the relative standard deviation obtained by analyzing a series of 10 replicates, was below 4% for all elements. The practical applicability of the developed sorbent was examined using synthetic seawater, natural waters and ceramic samples.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20006073     DOI: 10.1016/j.talanta.2009.09.007

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  A new method for the preconcentrations of U(VI) and Th(IV) by magnetized thermophilic bacteria as a novel biosorbent.

Authors:  Ersin Kılınç; Sadin Ozdemir; M Serkan Yalçın; Mustafa Soylak
Journal:  Anal Bioanal Chem       Date:  2021-01-02       Impact factor: 4.142

2.  Simultaneous spectrophotometric determination of trace amount of polycyclic aromatic hydrocarbons in water samples after magnetic solid-phase extraction by using projection pursuit regression.

Authors:  Jahan B Ghasemi; E Zolfonoun
Journal:  Environ Monit Assess       Date:  2012-06-12       Impact factor: 2.513

3.  Determination of trace amounts of zirconium in real samples after microwave digestion and ternary complex dispersive liquid-liquid microextraction.

Authors:  Daryoush Afzali; Fariba Fathirad; Sima Ghaseminezhad; Zahra Afzali
Journal:  Environ Monit Assess       Date:  2014-02-01       Impact factor: 2.513

4.  Ultrasound-assisted ionic liquid-based microextraction combined with least squares support vector machines regression for the simultaneous determination of aluminum, gallium, and indium in water and coal samples.

Authors:  Jahan B Ghasemi; Ehsan Zolfonoun
Journal:  Environ Monit Assess       Date:  2011-07-27       Impact factor: 2.513

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.