Literature DB >> 20003874

Minimally invasive treatment of distal tibial fractures with locking and non-locking plates.

Ufuk Ozkaya1, Atilla S Parmaksizoglu, Murat Gul, Sami Sokucu, Yavuz Kabukcuoglu.   

Abstract

BACKGROUND: The purpose of this study was to evaluate the clinical performances of stainless steel nonlocking plates and titanium locking plates in minimally invasive medial plating of extra-articular metaphyseal fractures of the distal tibia.
MATERIALS AND METHODS: Between 2004 and 2006, 43 patients who sustained closed fractures of the distal tibia metaphysis were managed with either a stainless steel nonlocking plate (Group 1, n = 21) or a titanium locking plate (Group 2, n = 22). Clinical and radiographic data were retrospectively reviewed. Function was assessed with use of the American Orthopaedic Foot and Ankle Society ankle-hindfoot instrument. The average followup period was 25 months.
RESULTS: The average AOFAS foot and ankle scores in Group 1 and Group 2 at final followup were 85 and 81, respectively. Fracture reduction was anatomical or nearly anatomical without angular displacement in all cases except one patient in Group 2. (p > 0.05) The average time to full, unprotected weightbearing in Group 1 and Group 2 were 15 weeks and 18 weeks, respectively (p < 0.05).
CONCLUSION: Minimally invasive medial plating with titanium locking plates resulted in prolonged secondary healing both in comminuted and simple fracture patterns compared to conventional stainless steel nonlocking plates. We believe that in biological fixation of distal tibial fractures, similarly good results may be obtained with both materials as the locking technology had a greater effect on stability.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20003874     DOI: 10.3113/FAI.2009.1161

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  4 in total

Review 1.  Plate fixation versus intramedullary nailing for displaced extra-articular distal tibia fractures: a system review.

Authors:  Bo Li; Yuehua Yang; Lei-Sheng Jiang
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

Review 2.  Distal tibia fractures: locked or non-locked plating? A systematic review of outcomes.

Authors:  Amrit S Khalsa; Nader Toossi; Loni P Tabb; Nirav H Amin; Kenneth W Donohue; Douglas L Cerynik
Journal:  Acta Orthop       Date:  2014-04-23       Impact factor: 3.717

3.  Locking versus Non-locking Neutralization Plates with Limited Excision and Internal Fixation for Treatment of Extra-articular Type a Distal Tibial Fractures.

Authors:  Kai-Hua Zhou; Nong Chen
Journal:  Open Orthop J       Date:  2017-02-28

4.  A systematic review of the use of titanium versus stainless steel implants for fracture fixation.

Authors:  Collin C Barber; Matthew Burnham; Ogaga Ojameruaye; Michael D McKee
Journal:  OTA Int       Date:  2021-08-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.