Literature DB >> 20003019

Safety and feasibility of real time adenosine myocardial contrast echocardiography with emphasis on induction of arrhythmias: a study in healthy volunteers and patients with stable coronary artery disease.

P A Dijkmans1, L J M Juffermans, J van Dijk, R J P Musters, O Kamp.   

Abstract

INTRODUCTION: Some studies reported an increased incidence of premature ventricular complexes (PVCs) during triggered myocardial contrast echocardiography (MCE) using high-intensity ultrasound destruction. Whether PVCs are also induced by real time MCE using low emission power, is unknown. The aim of the study was to assess the occurrence of arrhythmias during real time adenosine MCE in healthy volunteers and patients with stable coronary artery disease (CAD).
METHODS: Fifty healthy volunteers and 26 patients with stable CAD underwent real time MCE using Sonovue and power pulse inversion (ATL 5000) at rest and during adenosine stress. The occurrence of premature atrial complexes (PAC) and PVCs was analyzed before and during MCE using ECG-tracings from videotapes.
RESULTS: In healthy subjects, the occurrence of PVCs at baseline (0.04 +/- 0.23 PVCs/min) was similar at rest (0.04 +/- 0.23 PVCs/min, P = NS), and adenosine stress (0.03 +/- 0.14, P = NS). In CAD patients, the occurrence of PVCs at baseline was 0.30 +/- 0.76 PVC/min, compared to 0.29 +/- 0.74 at rest (P = NS), and 0.34 +/- 0.74 during adenosine stress (P = NS). The number of subjects demonstrating PVCs did not increase during MCE. The occurrence of PACs during MCE was not increased compared to baseline.
CONCLUSION: Real time MCE using low emission power does not increase the occurrence of premature complexes in healthy volunteers or CAD patients.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20003019     DOI: 10.1111/j.1540-8175.2008.00890.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  2 in total

1.  Ultrasound and microbubble-targeted delivery of therapeutic compounds: ICIN Report Project 49: Drug and gene delivery through ultrasound and microbubbles.

Authors:  L J M Juffermans; D B M Meijering; A van Wamel; R H Henning; K Kooiman; M Emmer; N de Jong; W H van Gilst; R Musters; W J Paulus; A C van Rossum; L E Deelman; O Kamp
Journal:  Neth Heart J       Date:  2009-02       Impact factor: 2.380

2.  The effect of contrast medium SonoVue® on the electric charge density of blood cells.

Authors:  Aneta D Petelska; Jacek R Janica; Joanna Kotynska; Urszula Łebkowska; Zbigniew A Figaszewski
Journal:  J Membr Biol       Date:  2011-11-24       Impact factor: 1.843

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.