Literature DB >> 20001476

Efficacy of plain radiography and computer tomography in localizing the site of pelvic arterial bleeding in trauma patients.

Johann B Dormagen1, Anna Tötterman, Olav Røise, Leiv Sandvik, Nils-E Kløw.   

Abstract

BACKGROUND: Immediate angiography is warranted in pelvic trauma patients with suspected arterial injury (AI) in order to stop ongoing bleeding. Prior to angiography, plain pelvic radiography (PPR) and abdominopelvic computer tomography (CT) are performed to identify fracture and hematoma sites.
PURPOSE: To investigate if PPR and CT can identify the location of AI in trauma patients undergoing angiography.
MATERIAL AND METHODS: 95 patients with pelvic fractures on PPR (29 women, 66 men), at a mean age of 44 (9-92) years, underwent pelvic angiography for suspected AI. Fifty-six of them underwent CT additionally. Right and left anterior and posterior fractures on PPR were registered, and fracture displacement was recorded for each quadrant. Arterial blush on CT was registered, and the size of the hematoma in each region was measured in cm(2). AIs were registered for anterior and posterior segments of both internal iliac arteries. Presence of fractures, arterial blush, and hematomas were correlated with AI.
RESULTS: Presence of fracture in the corresponding skeletal segment on PPR showed sensitivity and specificity of 0.86 and 0.58 posteriorly, and 0.87 and 0.44 anteriorly. The area under the curve (AUC) was 0.77 and 0.69, respectively. Fracture displacement on PPR >0.9 cm posteriorly and >1.9 cm anteriorly revealed specificity of 0.84. Sensitivities of arterial blush and hematoma on CT were 0.38 and 0.82 posteriorly, and 0.24 and 0.82 anteriorly. The specificities were 0.96 and 0.58 posteriorly, and 0.79 and 0.53 anteriorly, respectively. For hematomas, the AUC was 0.79 posteriorly and 0.75 anteriorly. Size of hematoma >22 cm(2) posteriorly and >29 cm(2) anteriorly revealed specificity of 0.85 and 0.86, respectively.
CONCLUSION: CT findings of arterial blush and hematoma predicted site of arterial bleeding on pelvic angiography. Also, PPR predicted the site of bleeding using location of fracture and size of displacement. In the hemodynamically unstable patient, PPR may contribute equally to effective assessment of injured arteries.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20001476     DOI: 10.3109/02841850903286703

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  5 in total

1.  Distribution of radiation exposure in patients with partially stable and unstable pelvic ring fractures: first-time use of highly accurate assessment by Monte Carlo calculations.

Authors:  Jakob C F Gunneweg; Georgios F Giannakopoulos; Wietse P Zuidema; Niels A A Matheijssen; Ferco H Berger
Journal:  Eur J Trauma Emerg Surg       Date:  2020-01-09       Impact factor: 3.693

2.  Variability in Uremic Control during Continuous Venovenous Hemodiafiltration in Trauma Patients.

Authors:  Sigrid Beitland; Kjetil Sunde; Harald Moen; Ingrid Os
Journal:  Crit Care Res Pract       Date:  2012-05-17

3.  Fracture of the acetabulum with femoral artery injury presenting late: A case report.

Authors:  Sivaprasad Kalyanasundaram; Venugopal K Menon; Jacob Varughese; Yasser Abbas Anis Hassan
Journal:  Trauma Case Rep       Date:  2016-04-13

4.  Accuracy of Contrast Extravasation on Computed Tomography for Diagnosing Severe Pelvic Hemorrhage in Pelvic Trauma Patients: A Meta-Analysis.

Authors:  Sung Nam Moon; Jung-Soo Pyo; Wu Seong Kang
Journal:  Medicina (Kaunas)       Date:  2021-01-12       Impact factor: 2.430

5.  The selection of diagnostic modalities in the management of pelvic fracture patients requiring transfers.

Authors:  Chih-Yuan Fu; Shang-Ju Yang; Chien-Hung Liao; Being-Chuan Lin; Shih-Ching Kang; Shang-Yu Wang; Yu-Pao Hsu
Journal:  World J Emerg Surg       Date:  2015-07-30       Impact factor: 5.469

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.