BACKGROUND: Primary repair of large hiatal hernia is associated with a high recurrence rate. The use of mesh may reduce this recurrence rate. The indication for mesh use, the type of mesh to use, and the placement technique are controversial. A survey of surgeon practice was undertaken to obtain a better understanding of the controversies surrounding this clinical problem. METHODS: A questionnaire on the technique and results of mesh hiatal herniorrhaphy was sent to 1,192 members of the Society of Gastrointestinal and Endoscopic Surgeons (SAGES). RESULTS: There were 275 responses; 261 of these were analyzed. A total of 5,486 hiatal hernia repairs with mesh were reported; 77% and 23% were performed laparoscopically vs open, respectively. The most common indication for mesh usage was an increased size hiatal defect (46% of respondents). The most common mesh types were biomaterial (28%), polytetrafluoroethylene (25%), and polypropylene (21%). Suture anchorage was the most common fixation technique (56% of respondents). The findings showed a failure rate of 3%, a stricture rate of 0.2%, and an erosion rate of 0.3%. Biomaterial tended to be associated with failure, whereas nonabsorbable mesh tended to be associated with stricture and erosion. CONCLUSIONS: The use of mesh during hiatal hernia repair resulted in a reported recurrence rate which appeared to be lower than that obtained historically without mesh. No one mesh type was clearly superior in terms of avoiding failure and complication.
BACKGROUND: Primary repair of large hiatal hernia is associated with a high recurrence rate. The use of mesh may reduce this recurrence rate. The indication for mesh use, the type of mesh to use, and the placement technique are controversial. A survey of surgeon practice was undertaken to obtain a better understanding of the controversies surrounding this clinical problem. METHODS: A questionnaire on the technique and results of mesh hiatal herniorrhaphy was sent to 1,192 members of the Society of Gastrointestinal and Endoscopic Surgeons (SAGES). RESULTS: There were 275 responses; 261 of these were analyzed. A total of 5,486 hiatal hernia repairs with mesh were reported; 77% and 23% were performed laparoscopically vs open, respectively. The most common indication for mesh usage was an increased size hiatal defect (46% of respondents). The most common mesh types were biomaterial (28%), polytetrafluoroethylene (25%), and polypropylene (21%). Suture anchorage was the most common fixation technique (56% of respondents). The findings showed a failure rate of 3%, a stricture rate of 0.2%, and an erosion rate of 0.3%. Biomaterial tended to be associated with failure, whereas nonabsorbable mesh tended to be associated with stricture and erosion. CONCLUSIONS: The use of mesh during hiatal hernia repair resulted in a reported recurrence rate which appeared to be lower than that obtained historically without mesh. No one mesh type was clearly superior in terms of avoiding failure and complication.
Authors: Frank A Granderath; Ursula M Schweiger; Thomas Kamolz; Martin Pasiut; Christoph F Haas; Rudolph Pointner Journal: J Gastrointest Surg Date: 2002 May-Jun Impact factor: 3.452
Authors: Rudolf J Stadlhuber; Amr El Sherif; Sumeet K Mittal; Robert J Fitzgibbons; L Michael Brunt; John G Hunter; Tom R Demeester; Lee L Swanstrom; C Daniel Smith; Charles J Filipi Journal: Surg Endosc Date: 2008-12-06 Impact factor: 4.584
Authors: Jan H Koetje; Jelmer E Oor; David J Roks; Henderik L Van Westreenen; Eric J Hazebroek; Vincent B Nieuwenhuijs Journal: Surg Endosc Date: 2017-01-11 Impact factor: 4.584
Authors: Jeremy R Huddy; Sheraz R Markar; Melody Z Ni; Mario Morino; Edoardo M Targarona; Giovanni Zaninotto; George B Hanna Journal: Surg Endosc Date: 2016-04-29 Impact factor: 4.584
Authors: Michael T Olson; Saurabh Singhal; Roshan Panchanathan; Sreeja Biswas Roy; Paul Kang; Taylor Ipsen; Sumeet K Mittal; Jasmine L Huang; Michael A Smith; Ross M Bremner Journal: Surg Endosc Date: 2018-05-14 Impact factor: 4.584