Literature DB >> 19996815

Determinants of contrast sensitivity for the tumbling E and Landolt C.

Kenneth R Alexander1, J Jason McAnany.   

Abstract

PURPOSE: To compare the object spatial frequencies that underlie contrast sensitivity for the tumbling E and Landolt C across a range of optotype sizes and under conditions biased toward the magnocellular (MC) and parvocellular (PC) pathways.
METHODS: Contrast thresholds of two visually normal observers were measured using tumbling E optotypes that were either low-pass filtered or high-pass filtered with a two-dimensional Gaussian filter. Optotypes were presented using steady-pedestal and pulsed-pedestal paradigms to target the MC and PC pathways, respectively. Object frequencies essential for orientation judgments of the tumbling E were derived from plots of log contrast threshold vs. log filter cutoff frequency, and results were compared with those obtained previously for the Landolt C under identical testing conditions.
RESULTS: The object frequency used to judge the orientation of the tumbling E increased systematically with increasing target angular subtense, and the effect of target size differed depending on whether performance was mediated by the inferred MC or PC pathway. The overall pattern of results was similar for the tumbling E and Landolt C, but there was generally less dependence of object frequency on target angular subtense for the tumbling E.
CONCLUSIONS: The tumbling E and Landolt C are not equivalent in terms of the object frequencies that mediate orientation judgments. However, both optotypes show scale-dependent changes in object frequency, particularly under test conditions that favor the PC pathway. The scale dependence of these broadband optotypes can pose a challenge in interpreting test results using these targets. A potential solution is to use spatially filtered optotypes with limited, known object frequency content.

Entities:  

Mesh:

Year:  2010        PMID: 19996815      PMCID: PMC2802654          DOI: 10.1097/OPX.0b013e3181c61117

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  36 in total

1.  Foveal and peripheral thresholds for detection and resolution of vanishing optotype tumbling E's.

Authors:  R S Anderson; F A Ennis
Journal:  Vision Res       Date:  1999       Impact factor: 1.886

2.  Characteristics of contrast processing deficits in X-linked retinoschisis.

Authors:  Kenneth R Alexander; Claire S Barnes; Gerald A Fishman
Journal:  Vision Res       Date:  2005-07       Impact factor: 1.886

3.  Measuring contrast sensitivity under different lighting conditions: comparison of three tests.

Authors:  Jens Bühren; Evdoxia Terzi; Michael Bach; Wolfgang Wesemann; Thomas Kohnen
Journal:  Optom Vis Sci       Date:  2006-05       Impact factor: 1.973

4.  Repeatability of visual acuity measurement.

Authors:  T W Raasch; I L Bailey; M A Bullimore
Journal:  Optom Vis Sci       Date:  1998-05       Impact factor: 1.973

5.  Relationship between acuity for gratings and for tumbling-E letters in peripheral vision.

Authors:  R S Anderson; L N Thibos
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1999-10       Impact factor: 2.129

6.  Computer-based test to measure optimal visual acuity in age-related macular degeneration.

Authors:  Esther G González; Luminita Tarita-Nistor; Samuel N Markowitz; Martin J Steinbach
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-10       Impact factor: 4.799

7.  Spatial frequencies used in Landolt C orientation judgments: relation to inferred magnocellular and parvocellular pathways.

Authors:  J Jason McAnany; Kenneth R Alexander
Journal:  Vision Res       Date:  2008-04-18       Impact factor: 1.886

8.  Optical quality of the eye in subjects with normal and excellent visual acuity.

Authors:  Eloy A Villegas; Encarna Alcón; Pablo Artal
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-06-14       Impact factor: 4.799

9.  The Freiburg Visual Acuity Test-variability unchanged by post-hoc re-analysis.

Authors:  Michael Bach
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2007-01-12       Impact factor: 3.535

10.  Vision improvement by correcting higher-order aberrations with phase plates in normal eyes.

Authors:  Geunyoung Yoon; Tae Moon Jeong; Ian G Cox; David R Williams
Journal:  J Refract Surg       Date:  2004 Sep-Oct       Impact factor: 3.573

View more
  7 in total

1.  Object frequency characteristics of visual acuity.

Authors:  J Jason McAnany; Kenneth R Alexander; Jennifer I Lim; Mahnaz Shahidi
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-12-16       Impact factor: 4.799

2.  Designing a new test for contrast sensitivity function measurement with iPad.

Authors:  Manuel Rodríguez-Vallejo; Laura Remón; Juan A Monsoriu; Walter D Furlan
Journal:  J Optom       Date:  2014-07-11

3.  Contributions of optical and non-optical blur to variation in visual acuity.

Authors:  J Jason McAnany; Mahnaz Shahidi; Raymond A Applegate; Ruth Zelkha; Kenneth R Alexander
Journal:  Optom Vis Sci       Date:  2011-06       Impact factor: 1.973

4.  The effect of exposure duration on visual acuity for letter optotypes and gratings.

Authors:  J Jason McAnany
Journal:  Vision Res       Date:  2014-10-02       Impact factor: 1.886

5.  Development of a Spatio-temporal Contrast Sensitivity Test for Clinical Use.

Authors:  Marcelo Fernandes Costa; Leonardo Dutra Henriques; Otávio Côrrea Pinho
Journal:  J Ophthalmic Vis Res       Date:  2022-01-21

6.  Effect of luminance noise on the object frequencies mediating letter identification.

Authors:  Cierra Hall; Shu Wang; Reema Bhagat; J Jason McAnany
Journal:  Front Psychol       Date:  2014-07-03

7.  Luminance noise as a novel approach for measuring contrast sensitivity within the magnocellular and parvocellular pathways.

Authors:  Cierra M Hall; J Jason McAnany
Journal:  J Vis       Date:  2017-07-01       Impact factor: 2.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.