Literature DB >> 19996518

Comparison of three instruments for measuring red blood cell aggregation.

Oguz K Baskurt1, Mehmet Uyuklu, Pinar Ulker, Melike Cengiz, Norbert Nemeth, Tamas Alexy, Sehyun Shin, Max R Hardeman, Herbert J Meiselman.   

Abstract

The International Society for Clinical Hemorheology organized a workshop to compare three instruments for measuring RBC aggregation: LORCA, Myrenne Aggregometer and RheoScan-A. The Myrenne Aggregometer provides indices at stasis (M) and at low shear (M1), with four indices obtained with the LORCA and RheoScan-A: amplitude (AMP), half-time (T1/2), surface area (SA) above (LORCA) or below (RheoScan-A) the syllectogram, and the ratio (AI) of the area above (LORCA) or below (RheoScan-A) the syllectogram to total area (AI). Intra-assay reproducibility and biological variability were determined; also studied were RBC in diluted plasma and in 1% 500 kDa dextran, and 0.003% glutaradehyde (GA)-treated cells in plasma. All measurements were performed at 37 degrees C. Standardized difference values were used as a measure of power to detect differences. Salient results were: (1) intra-assay variations below 5% except for RheoScan-A AMP and SA; (2) biological variability greatest for T1/2 with other indices similar for the three devices; (3) all instruments detected progressive changes with plasma dilution; (4) the Myrenne and LORCA, but not the RheoScan-A, detected differences for cells in dextran; (5) GA-treatment significantly affected the LORCA (AMP, T1/2, SA, AI), the RheoScan-A (AMP, SA, AI) and the Myrenne M parameter. It is concluded that: (a) the LORCA, Myrenne and the RheoScan-A have acceptable precision and suitable power for detecting reduced aggregation due to plasma dilution; (b) greatly enhanced RBC aggregation may not be sensed by the RheoScan-A while the Myrenne M1 index may be insensitive to minor increases of cell rigidity; (c) future studies should define each instrument's useful range for detecting RBC aggregation.

Entities:  

Mesh:

Year:  2009        PMID: 19996518     DOI: 10.3233/CH-2009-1240

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  15 in total

1.  Wavelength selection in measuring red blood cell aggregation based on light transmittance.

Authors:  Mehmet Uyuklu; Murat Canpolat; Herbert J Meiselman; Oguz K Baskurt
Journal:  J Biomed Opt       Date:  2011-11       Impact factor: 3.170

2.  Quantification of Inter-Erythrocyte Forces with Ultra-High Frequency (410 MHz) Single Beam Acoustic Tweezer.

Authors:  Hae Gyun Lim; K Kirk Shung
Journal:  Ann Biomed Eng       Date:  2017-05-30       Impact factor: 3.934

Review 3.  Mechanical blood trauma in assisted circulation: sublethal RBC damage preceding hemolysis.

Authors:  Salim E Olia; Timothy M Maul; James F Antaki; Marina V Kameneva
Journal:  Int J Artif Organs       Date:  2016-03-30       Impact factor: 1.595

4.  Elevated Low-Shear Blood Viscosity is Associated with Decreased Pulmonary Blood Flow in Children with Univentricular Heart Defects.

Authors:  Andrew L Cheng; Cheryl M Takao; Rosalinda B Wenby; Herbert J Meiselman; John C Wood; Jon A Detterich
Journal:  Pediatr Cardiol       Date:  2016-02-18       Impact factor: 1.655

5.  Partitioning of red blood cell aggregates in bifurcating microscale flows.

Authors:  E Kaliviotis; J M Sherwood; S Balabani
Journal:  Sci Rep       Date:  2017-03-17       Impact factor: 4.379

Review 6.  Potential Diagnostic Hemorheological Indexes for Chronic Kidney Disease in Patients With Type 2 Diabetes.

Authors:  Hoyoon Lee; Wonwhi Na; Sang Bae Lee; Chul Woo Ahn; Jun Sung Moon; Kyu Chang Won; Sehyun Shin
Journal:  Front Physiol       Date:  2019-08-20       Impact factor: 4.566

Review 7.  The Relationship Between Aggregation and Deformability of Red Blood Cells in Health and Disease.

Authors:  Dan Lazari; Joames Kauffimann Freitas Leal; Roland Brock; Giel Bosman
Journal:  Front Physiol       Date:  2020-04-15       Impact factor: 4.566

8.  Influence of Pulsed He-Ne Laser Irradiation on the Red Blood Cell Interaction Studied by Optical Tweezers.

Authors:  Ruixue Zhu; Tatiana Avsievich; Alexander Bykov; Alexey Popov; Igor Meglinski
Journal:  Micromachines (Basel)       Date:  2019-12-05       Impact factor: 2.891

9.  Optofluidic laser speckle image decorrelation analysis for the assessment of red blood cell storage.

Authors:  Hee-Jae Jeon; Muhammad Mohsin Qureshi; Seung Yeob Lee; Euiheon Chung
Journal:  PLoS One       Date:  2019-10-22       Impact factor: 3.240

10.  Impact of A Six Week Training Program on Ventilatory Efficiency, Red Blood Cell Rheological Parameters and Red Blood Cell Nitric Oxide Signaling in Young Sickle Cell Anemia Patients: A Pilot Study.

Authors:  Marijke Grau; Elie Nader; Max Jerke; Alexander Schenk; Celine Renoux; Thomas Dietz; Bianca Collins; Daniel Alexander Bizjak; Philippe Joly; Wilhelm Bloch; Aram Prokop; Philippe Connes
Journal:  J Clin Med       Date:  2019-12-05       Impact factor: 4.241

View more