Value of ventricular electrogram recordings in the diagnosis of arrhythmias precipitating electrical device shock therapy.

B G Hook1, F E Marchlinski.   

Abstract

An antitachycardia pacemaker-cardioverter-defibrillator that is capable of storing ventricular electrograms before and after delivery of device shock therapy was implanted in 16 patients. Three of the patients experienced out-of-hospital device shock therapy preceded by minimal symptoms. Although limitations of electrogram analysis exist and are discussed, careful analysis and registration of electrograms during all supraventricular and ventricular rhythms observed during in-hospital testing served as an important reference for subsequent arrhythmia diagnosis. By analyzing the electrogram rate and RR interval stability and configuration, a definitive diagnosis was established in all three patients (atrial fibrillation, polymorphic ventricular tachycardia and rate-sensing lead disruption, respectively). Thus, the ability to store ventricular electrograms before shock therapy represents a major advance in the management of patients who receive an electrical device to treat ventricular tachyarrhythmia.

Entities:  

Mesh:

Year:  1991        PMID: 1999638     DOI: 10.1016/0735-1097(91)90884-c

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  13 in total

1.  Prospective evaluation of the quality and long-term stability of atrial signals in non-thoracotomy defibrillation electrodes: comparison of four different endocardial electrograms.

Authors:  C Wolpert; W Jung; S Spehl; B Schumacher; H Omran; B Esmailzadeh; B Lüderitz
Journal:  J Interv Card Electrophysiol       Date:  1998-12       Impact factor: 1.900

2.  Triggers of sustained monomorphic ventricular tachycardia differ among patients with varying etiologies of left ventricular dysfunction.

Authors:  Jonathan Rosman; Sam Hanon; Michael Shapiro; Steven J Evans; Paul Schweitzer
Journal:  Ann Noninvasive Electrocardiol       Date:  2006-04       Impact factor: 1.468

3.  Pattern of initiation of monomorphic ventricular tachycardia in recorded intracardiac electrograms.

Authors:  Majid Haghjoo; Arash Arya; Mohammad Ali Sadr-Ameli
Journal:  Indian Pacing Electrophysiol J       Date:  2005-10-01

4.  Case report: inappropriate discharge of an implantable cardioverter-defibrillator caused by the combined count criterion.

Authors:  C Wolpert; W Jung; S Spehl; T Korte; B Lüderitz
Journal:  J Interv Card Electrophysiol       Date:  1998-03       Impact factor: 1.900

5.  A pilot study examining the performance of polynomial-modeled ventricular shock electrograms for rhythm discrimination in implantable devices.

Authors:  Jeffrey L Williams; Vladimir Shusterman; Samir Saba
Journal:  Pacing Clin Electrophysiol       Date:  2006-09       Impact factor: 1.976

6.  Implantable cardioverter defibrillator-an unusual case of inappropriate discharge during showering.

Authors:  A G Manolis; A G Katsivas; C V Vassilopoulos; N E Louvros
Journal:  J Interv Card Electrophysiol       Date:  2000-04       Impact factor: 1.900

7.  Beta-blocker therapy is associated with a lower incidence of syncope due to fast ventricular tachycardias among implantable cardioverter-defibrillator patients with left ventricular dysfunction: results from a multicenter study.

Authors:  Javier Jiménez-Candil; Ignasi Anguera; Olga Durán; Jesús Hernández; Javier Fernández-Portales; José Luis Moríñigo; Ana Martín; Paolo Dallaglio; Loreto Bravo; Andrea di Marco; Pedro Luis Sánchez
Journal:  J Interv Card Electrophysiol       Date:  2018-03-20       Impact factor: 1.900

8.  Efficacy of a tiered therapy defibrillator system used to treat recurrent ventricular arrhythmias refractory to drugs.

Authors:  A C Rankin; S Zaim; A Powell; B Zaim; R Brooks; B A McGovern; H Garan; J N Ruskin
Journal:  Br Heart J       Date:  1993-07

9.  Volumetric left ventricular ejection fraction is superior to 2-dimensional echocardiography for risk stratification of patients for primary prevention implantable cardioverter-defibrillator implantation.

Authors:  Hussein Rayatzadeh; Shalin J Patel; Thomas H Hauser; Long L Ngo; Jaime L Shaw; Alex Tan; Alfred E Buxton; Peter Zimetbaum; Mark E Josephson; Evan Appelbaum; Warren J Manning; Reza Nezafat
Journal:  Am J Cardiol       Date:  2013-02-01       Impact factor: 2.778

10.  Effectiveness of first versus successive antitachycardia pacing attempts: predictors and clinical consequences.

Authors:  Javier Jiménez-Candil; Olga Durán; Jean Núñez; Loreto Bravo; Jesús Hernández; Ana Martín-García; José Morínigo; Pedro L Sánchez
Journal:  J Interv Card Electrophysiol       Date:  2019-09-16       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.