Compact x-ray sources for mammographic applications: Monte Carlo simulations of image quality.

P Oliva1, B Golosio, S Stumbo, A Bravin, P Tomassini.   

Abstract

Thomson scattering x-ray sources can provide spectral distributions that are ideally suited for mammography with sufficient fluence rates. In this article, the authors investigate the effects of different spectral distributions on the image quality in simulated images of a breast mammographic phantom containing details of different compositions and thicknesses. They simulated monochromatic, quasimonochromatic, and polychromatic x-ray sources in order to define the energy for maximum figure of merit (signal-difference-to-noise ratio squared/mean glandular dose), the effect of an energy spread, and the effect of the presence of higher-order harmonics. The advantages of these sources with respect to conventional polychromatic sources as a function of phantom and detail thickness were also investigated. The results show that the energy for the figure of merit peak is between 16 and 27.4 keV, depending on the phantom thickness and detail composition and thickness. An energy spread of about 1 keV standard deviation, easily achievable with compact x-ray sources, does not appreciably affect the image quality.

Mesh:

Year:  2009        PMID: 19994525     DOI: 10.1118/1.3245876

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Optimization of the energy for Breast monochromatic absorption X-ray Computed Tomography.

Authors:  Pasquale Delogu; Vittorio Di Trapani; Luca Brombal; Giovanni Mettivier; Angelo Taibi; Piernicola Oliva
Journal:  Sci Rep       Date:  2019-09-11       Impact factor: 4.379

2.  Contrast-enhanced spectral mammography with a compact synchrotron source.

Authors:  Lisa Heck; Martin Dierolf; Christoph Jud; Elena Eggl; Thorsten Sellerer; Korbinian Mechlem; Benedikt Günther; Klaus Achterhold; Bernhard Gleich; Stephan Metz; Daniela Pfeiffer; Kevin Kröninger; Julia Herzen
Journal:  PLoS One       Date:  2019-10-10       Impact factor: 3.240

3.  Experimental optimization of the energy for breast-CT with synchrotron radiation.

Authors:  Piernicola Oliva; Vittorio Di Trapani; Fulvia Arfelli; Luca Brombal; Sandro Donato; Bruno Golosio; Renata Longo; Giovanni Mettivier; Luigi Rigon; Angelo Taibi; Giuliana Tromba; Fabrizio Zanconati; Pasquale Delogu
Journal:  Sci Rep       Date:  2020-10-15       Impact factor: 4.379

4.  Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes.

Authors:  Giovanni Mettivier; Antonio Sarno; Youfang Lai; Bruno Golosio; Viviana Fanti; Maria Elena Italiano; Xun Jia; Paolo Russo
Journal:  Cancers (Basel)       Date:  2022-02-17       Impact factor: 6.639

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.