Literature DB >> 1998640

Quantification of fibrin deposition in flowing blood with peroxidase-labeled fibrinogen. High shear rates induce decreased fibrin deposition and appearance of fibrin monomers.

P N Tijburg1, M J Ijsseldijk, J J Sixma, P G de Groot.   

Abstract

To study fibrin incorporation into thrombi at different wall shear rates, a new method to study fibrin deposition on extracellular matrixes underlying stimulated endothelial cells under flow conditions was developed. For this method, we used fibrinogen labeled with peroxidase (Fg-PO). Fg-PO was fully exchangeable for Fg in the clotting assays tested, and PO activity was bound to fibrin-specific fragments. Fg-PO containing fibrin could be stained for microscopic studies with 3,3'-diaminobenzidine and could be quantified by oxidation of phenylenediamine. The absorbance values at 492 nm were converted to fibrin quantities via a standard curve. To study fibrin deposition, Fg-PO was added in trace amounts to whole blood anticoagulated with low-molecular-weight heparin, and perfusion studies were performed over endothelial cell matrixes containing tissue factor. In parallel perfusion studies, 125I-labeled Fg was added in trace amounts to whole blood instead of Fg-PO. Both quantitative methods demonstrated decreased fibrin deposition after perfusions at 1,300 sec-1 compared with fibrin deposition after perfusions at 300 sec-1, while fibrinopeptide A generation was independent of the wall shear rate. The decrease in fibrin deposition at 1,300 sec-1 was accompanied by the appearance of fibrin monomers in the perfusate. This suggested that the decrease in fibrin incorporation at 1,300 sec-1 was due to the impaired polymerization of fibrin monomers. This impairment was probably due to a decrease in local fibrin monomer concentration as a result of the increased removal of monomers from the surface at 1,300 sec-1.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1998640     DOI: 10.1161/01.atv.11.2.211

Source DB:  PubMed          Journal:  Arterioscler Thromb        ISSN: 1049-8834


  8 in total

Review 1.  Shear-dependence of endothelial functions.

Authors:  W H Reinhart
Journal:  Experientia       Date:  1994-02-15

2.  Thrombin flux and wall shear rate regulate fibrin fiber deposition state during polymerization under flow.

Authors:  K B Neeves; D A R Illing; S L Diamond
Journal:  Biophys J       Date:  2010-04-07       Impact factor: 4.033

3.  Endothelial cells stimulated with tumor necrosis factor-alpha express varying amounts of tissue factor resulting in inhomogenous fibrin deposition in a native blood flow system. Effects of thrombin inhibitors.

Authors:  D Kirchhofer; T B Tschopp; P Hadváry; H R Baumgartner
Journal:  J Clin Invest       Date:  1994-05       Impact factor: 14.808

Review 4.  Blood flow and mass transfer regulation of coagulation.

Authors:  Kuldeepsinh Rana; Keith B Neeves
Journal:  Blood Rev       Date:  2016-04-29       Impact factor: 8.250

Review 5.  Transport physics and biorheology in the setting of hemostasis and thrombosis.

Authors:  L F Brass; S L Diamond
Journal:  J Thromb Haemost       Date:  2016-03-30       Impact factor: 5.824

6.  Functional factor XIII-A is exposed on the stimulated platelet surface.

Authors:  Joanne L Mitchell; Ausra S Lionikiene; Steven R Fraser; Claire S Whyte; Nuala A Booth; Nicola J Mutch
Journal:  Blood       Date:  2014-10-20       Impact factor: 22.113

7.  Development of a mesoscopic framework spanning nanoscale protofibril dynamics to macro-scale fibrin clot formation.

Authors:  Naoki Takeishi; Taiki Shigematsu; Ryogo Enosaki; Shunichi Ishida; Satoshi Ii; Shigeo Wada
Journal:  J R Soc Interface       Date:  2021-11-10       Impact factor: 4.118

Review 8.  Biomechanics of haemostasis and thrombosis in health and disease: from the macro- to molecular scale.

Authors:  Reginald Tran; David R Myers; Jordan Ciciliano; Elaissa L Trybus Hardy; Yumiko Sakurai; Byungwook Ahn; Yongzhi Qiu; Robert G Mannino; Meredith E Fay; Wilbur A Lam
Journal:  J Cell Mol Med       Date:  2013-03-14       Impact factor: 5.310

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.