Literature DB >> 1997803

Static pre-load effect on knee extensor isokinetic concentric and eccentric performance.

R C Jensen1, B Warren, C Laursen, M C Morrissey.   

Abstract

The effect of two static pre-load levels on isokinetic concentric (CON) and eccentric (ECC) performance of the knee extensors at 90 degrees.s-1 was evaluated in 35 healthy subjects. The low pre-load level was 50 N, and the high level was 75% of a maximal voluntary isometric contraction, performed at the start angles of 100 degrees (CON) and 30 degrees (ECC) of knee flexion. A two-way ANOVA with two repeated measures (load and angle) and a Newman-Keuls post hoc analysis were performed to compare the interaction of pre-load and angle at every 5 degrees in the ROM. The differences in average torque, peak torque, and peak torque angle between the pre-load levels were also analyzed with repeated-measures t-tests. The high pre-load condition had a significant increase in torque at 99, 95, 90, and 85 degrees concentrically and 31, 35, 40, 45, and 50 degrees eccentrically. In comparing the two pre-load conditions over the whole torque curve, there was a significant difference in average torque values of both CON and ECC, no significant difference in peak torque in either contraction, and a significant shift in peak torque angle with CON contractions only.

Mesh:

Year:  1991        PMID: 1997803

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  7 in total

1.  Effect of unilateral functional instability of the ankle on postural sway and inversion and eversion strength.

Authors:  J N Bernier; D H Perrin; A Rijke
Journal:  J Athl Train       Date:  1997-07       Impact factor: 2.860

2.  Comparison of aspiration and scintigraphic techniques for the measurement of gastric emptying rates of liquids in humans.

Authors:  E J Beckers; J B Leiper; J Davidson
Journal:  Gut       Date:  1992-01       Impact factor: 23.059

3.  Reliability of lower extremity strength measures in persons with chronic stroke.

Authors:  Janice J Eng; C Maria Kim; Donna L Macintyre
Journal:  Arch Phys Med Rehabil       Date:  2002-03       Impact factor: 3.966

4.  Effect of prior isometric muscle action on concentric torque output during plantar flexion.

Authors:  M Peeters; U Svantesson; G Grimby
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

Review 5.  Isokinetic eccentric exercise.

Authors:  E Kellis; V Baltzopoulos
Journal:  Sports Med       Date:  1995-03       Impact factor: 11.136

6.  Factors of force potentiation induced by stretch-shortening cycle in plantarflexors.

Authors:  Atsuki Fukutani; Toshiyuki Kurihara; Tadao Isaka
Journal:  PLoS One       Date:  2015-06-01       Impact factor: 3.240

7.  Influence of joint angular velocity on electrically evoked concentric force potentiation induced by stretch-shortening cycle in young adults.

Authors:  Atsuki Fukutani; Toshiyuki Kurihara; Tadao Isaka
Journal:  Springerplus       Date:  2015-02-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.