Literature DB >> 19967670

Quantitative evaluation of anterior chamber changes after iridotomy using Pentacam anterior segment analyzer.

Cristina López-Caballero1, Beatriz Puerto-Hernández, Francisco J Muñoz-Negrete, Gema Rebolleda, Inés Contreras, Carmen Cabarga, Angeles Corral.   

Abstract

PURPOSE: To evaluate changes in anterior chamber morphology with the Pentacam anterior segment analyzer and gonioscopy after laser peripheral iridotomy (LPI) in patients with primary angle closure glaucoma and narrow angle and to compare central corneal thickness measurements performed with Pentacam and ultrasound pachymetry.
METHODS: Twenty eyes of 20 patients were enrolled in this prospective interventional study. Before and after LPI, volume, angle, and central and peripheral depth of anterior chamber was quantified with Pentacam. Central corneal thickness was measured with Pentacam and ultrasound pachymetry.
RESULTS: Mean central corneal thickness as measured with Pentacam pachymetry was slightly lower than the measurements provided by ultrasonic pachymetry (551.9 microm, range 509-659, versus 556.8 microm, range 520-644) (p=0.93) with an intraclass correlation coefficient of 0.92. Anterior chamber angle increased from 20.32 (standard deviation [SD] 4.2) to 22.31 degrees (SD 3.9). Anterior chamber central depth increased significantly from 1.79 mm (SD 0.22) to 1.85 mm (SD 0.21) and volume changed from 72.18 mm (SD 16.82) to 89.12 mm (SD 12.3), p=0.001. Gonioscopy showed that Shaffer angle widened significantly in all quadrants. Mean intraocular pressure changed from 20.8 mmHg to 18.3 mmHg after LPI (p<0.05).
CONCLUSIONS: In patients with primary angle closure glaucoma and narrow angles, anterior chamber volume, angle, and central and peripheral depth, measured with Pentacam, increase significantly after LPI.

Entities:  

Mesh:

Year:  2010        PMID: 19967670     DOI: 10.1177/112067211002000211

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  5 in total

1.  Assessment of the anterior chamber parameters after laser iridotomy in primary angle close suspect using Pentacam and gonioscopy.

Authors:  Alireza Esmaeili; Behzad Barazandeh; Sina Ahmadi; Alireza Haghi; Seyed Mahdi Ahmadi Hosseini; Fereshteh Abolbashari
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

2.  Pentacam changes in primary angle-closure glaucoma after different lines of treatment.

Authors:  Tharwat H Mokbel; Abd-Elmonem Elhesy; Ahmed Alnagdy; Mohammed F Elashri; Ahmed M Eissa; Walid M Gaafar; Sherein M Hagras
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

3.  Changes in ocular biometry and anterior chamber parameters after pharmacologic mydriasis and peripheral iridotomy in primary angle closure suspects.

Authors:  Mohammad Reza Razeghinejad; Hamid Lashkarizadeh; Mohammad Hossein Nowroozzadeh; Mohammad Yazdanmehr
Journal:  J Optom       Date:  2016-02-28

4.  Measurement of and Factors Associated with the Anterior Chamber Volume in Healthy Chinese Adults.

Authors:  Yuan Zong; Qian Xu; Chunhui Jiang; Haohao Zhu; Jian Yu; Xinghuai Sun
Journal:  J Ophthalmol       Date:  2017-01-10       Impact factor: 1.909

5.  Rate of central corneal thickness changes in primary angle closure eyes: long-term follow-up results.

Authors:  Hae Min Park; Jiin Choi; Won June Lee; Ki Bang Uhm
Journal:  BMC Ophthalmol       Date:  2021-03-22       Impact factor: 2.209

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.