Literature DB >> 19967668

Toxic anterior segment syndrome following iris-supported phakic IOL implantation with viscoelastic Multivisc BD.

Israel Kremer1, Eliya Levinger, Samuel Levinger.   

Abstract

PURPOSE: To report on the association between Multivisc BD and toxic anterior segment syndrome (TASS) post phakic intraocular lens (IOL) implantation.
METHODS: Two patients developed severe toxic anterior chamber inflammation following implantation of phakic iris fixated IOL with Multivisc BD viscoelastic. Anterior chamber washout was performed with intracameral antibiotic injection. Local antibiotics were continued until cultures were found to be negative. Thereafter, intensive local and systemic steroids were initiated and gradually tapered down.
RESULTS: The inflammatory reaction disappeared completely and the visual acuity improved from hand motion to 6/9 without correction within 1 week.
CONCLUSIONS: Any viscoelastic material may be contaminated by heat-stable bacterial endotoxic as it is prepared by gene-coded bacteria. It is suggested that Multivisc BD was the etiologic factor of TASS. Refractive surgeons should be aware of this rare complication of phakic IOL implantation whenever they use a new viscoelastic material.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19967668     DOI: 10.1177/112067211002000229

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  5 in total

1.  The role of patient's systemic characteristics and plateletcrit in developing toxic anterior segment syndrome after uneventful phaco surgery: A case-control study.

Authors:  Serpil Yazgan; Ugur Celik; Orhan Ayar; Suat Hayri Ugurbas; Burcu Celik; Mehmet Orçun Akdemir; Silay Canturk Ugurbas; Atilla Alpay
Journal:  Int Ophthalmol       Date:  2017-01-27       Impact factor: 2.031

2.  Unilateral Toxic Anterior Segment Syndrome Resulting in Cataract and Urrets-Zavalia Syndrome after Sequential Uneventful Implantation of a Posterior Chamber Phakic Toric Intraocular Lens at Two Different Surgical Facilities: A Series of Unfortunate Events.

Authors:  Kepa Balparda; Claudia Marcela Vanegas-Ramirez; Johny Márquez-Tróchez; Tatiana Herrera-Chalarca
Journal:  Case Rep Ophthalmol Med       Date:  2020-11-03

3.  Toxic anterior segment syndrome after foldable artiflex iris-fixated phakic intraocular lens implantation.

Authors:  Lucien A M van Philips
Journal:  J Ophthalmol       Date:  2011-06-05       Impact factor: 1.909

Review 4.  Toxic anterior segment syndrome-an updated review.

Authors:  Choul Yong Park; Jimmy K Lee; Roy S Chuck
Journal:  BMC Ophthalmol       Date:  2018-10-25       Impact factor: 2.209

Review 5.  Postoperative Endophthalmitis and Toxic Anterior Segment Syndrome Prophylaxis: 2020 Update.

Authors:  Jesse D Sengillo; Ying Chen; Diley Perez Garcia; Stephen G Schwartz; Andrzej Grzybowski; Harry W Flynn
Journal:  Ann Transl Med       Date:  2020-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.