Low cost and manufacturable complete microTAS for detecting bacteria.

Alexis F Sauer-Budge1, Paul Mirer, Anirban Chatterjee, Catherine M Klapperich, David Chargin, Andre Sharon.   

Abstract

In this paper, we present a fully integrated lab-on-a-chip and associated instrument for the detection of bacteria from liquid samples. The system conducts bacterial lysis, nucleic acid isolation and concentration, polymerase chain reaction (PCR), and end-point fluorescent detection. To enable truly low-cost manufacture of the single-use disposable chip, we designed the plastic chip in a planar format without any active components to be amenable to injection molding and utilized a novel porous polymer monolith (PPM) embedded with silica that has been shown to lyse bacteria and isolate the nucleic acids from clinical samples (M. D. Kulinski, M. Mahalanabis, S. Gillers, J. Y. Zhang, S. Singh and C. M. Klapperich, Biomed. Microdevices, 2009, 11, 671-678).(1) The chip is made of Zeonex(R), a thermoplastic with a high melting temperature to allow PCR, good UV transmissibility for UV-curing of the PPM, and low auto-fluorescence for fluorescence detection of the amplicon. We have built a prototype instrument to automate control of the fluids, temperature cycling, and optical detection with the capability of accommodating various chip designs. To enable fluid control without including valves or pumps on the chip, we utilized a remote valve switching technique. To allow fluid flow rate changes on the valveless chip, we incorporated speed changing fluid reservoirs. The PCR thermal cycling was achieved with a ceramic heater and air cooling, while end-point fluorescence detection was accomplished with an optical spectrometer; all integrated in the instrument. The chip seamlessly and automatically is mated to the instrument through an interface block that presses against the chip. The interface block aligns and ensures good contact of the chip to the temperature controlled region and the optics. The integrated functionality of the chip was demonstrated using Bacillus subtilis as a model bacterial target. A Taqman assay was employed on-chip to detect the isolated bacterial DNA.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19967117     DOI: 10.1039/b904854e

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  18 in total

1.  Thermoplastic microfluidic devices and their applications in protein and DNA analysis.

Authors:  Ke Liu; Z Hugh Fan
Journal:  Analyst       Date:  2011-01-28       Impact factor: 4.616

2.  A study of the fluorescence characteristics of common cariogenic microorganisms.

Authors:  Haihua Zhu; Weiwei Lao; Qingguang Chen; Qixia Zhang; Hui Chen
Journal:  Int J Clin Exp Med       Date:  2015-03-15

3.  A novel microbead-based microfluidic device for rapid bacterial identification and antibiotic susceptibility testing.

Authors:  J He; X Mu; Z Guo; H Hao; C Zhang; Z Zhao; Q Wang
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2014-07-05       Impact factor: 3.267

4.  Fully integrated thermoplastic genosensor for the highly sensitive detection and identification of multi-drug-resistant tuberculosis.

Authors:  Hong Wang; Hui-Wen Chen; Mateusz L Hupert; Pin-Chuan Chen; Proyag Datta; Tana L Pittman; Jost Goettert; Michael C Murphy; Diana Williams; Francis Barany; Steven A Soper
Journal:  Angew Chem Int Ed Engl       Date:  2012-03-19       Impact factor: 15.336

5.  Rapid antibiotic sensitivity testing in microwell arrays.

Authors:  Fatemeh Jalali; Felix Ellett; Daniel Irimia
Journal:  Technology (Singap World Sci)       Date:  2017-05-16

6.  Topography-assisted electromagnetic platform for blood-to-PCR in a droplet.

Authors:  Chi-Han Chiou; Dong Jin Shin; Yi Zhang; Tza-Huei Wang
Journal:  Biosens Bioelectron       Date:  2013-06-15       Impact factor: 10.618

7.  Isolation and amplification of mRNA within a simple microfluidic lab on a chip.

Authors:  Sarah J Reinholt; Arne Behrent; Cassandra Greene; Ayten Kalfe; Antje J Baeumner
Journal:  Anal Chem       Date:  2013-12-13       Impact factor: 6.986

8.  Emerging Microtechnologies and Automated Systems for Rapid Bacterial Identification and Antibiotic Susceptibility Testing.

Authors:  Yiyan Li; Xing Yang; Weian Zhao
Journal:  SLAS Technol       Date:  2017-08-29       Impact factor: 3.047

9.  A microfluidic platform for rapid, stress-induced antibiotic susceptibility testing of Staphylococcus aureus.

Authors:  Maxim Kalashnikov; Jean C Lee; Jennifer Campbell; Andre Sharon; Alexis F Sauer-Budge
Journal:  Lab Chip       Date:  2012-11-07       Impact factor: 6.799

10.  A microfluidic chip integrating DNA extraction and real-time PCR for the detection of bacteria in saliva.

Authors:  Emily A Oblath; W Hampton Henley; Jean Pierre Alarie; J Michael Ramsey
Journal:  Lab Chip       Date:  2013-04-07       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.