Literature DB >> 19967116

Temporal analysis of protozoan lysis in a microfluidic device.

Michael F Santillo1, Michael L Heien, Andrew G Ewing.   

Abstract

A microfluidic device was fabricated and characterized for studying cell lysis of Arcella vulgaris, a nonpathogenic amoeba, over time. The device contains a series of chambers which capture cells allowing them to be subsequently exposed to a constant flow of biocidal agent. With this microfluidic system, individual cells are observed as they undergo lysis. This allows high-throughput measurements of individual lysis events, which are not possible with conventional techniques. Differences in lysis and decay times for Arcella were seen at different flow rates and concentrations of benzalkonium chloride, a biocidal detergent. The efficacy of benzalkonium chloride, chlorhexidine digluconate, phenol, sodium dodecyl sulfate, and Triton X-100 were compared, revealing information on their mechanisms of action. The presented device allows cell capture, controlled exposure to chemical biocides, and observation of lysis with single-cell resolution. Observations at the single cell level give insight into the mechanistic details of the lysis of individual Arcella cells vs. the population; decay times for individual Arcella cells were much shorter when compared to a population of 15 cells.

Entities:  

Mesh:

Year:  2009        PMID: 19967116      PMCID: PMC4801346          DOI: 10.1039/b907942d

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  44 in total

Review 1.  Solubilization of membranes by detergents.

Authors:  A Helenius; K Simons
Journal:  Biochim Biophys Acta       Date:  1975-03-25

Review 2.  Interaction of membrane proteins and lipids with solubilizing detergents.

Authors:  M le Maire; P Champeil; J V Moller
Journal:  Biochim Biophys Acta       Date:  2000-11-23

3.  Dynamic single-cell analysis for quantitative biology.

Authors:  Dino Di Carlo; Luke P Lee
Journal:  Anal Chem       Date:  2006-12-01       Impact factor: 6.986

Review 4.  Modes of action of disinfectants.

Authors:  P Maris
Journal:  Rev Sci Tech       Date:  1995-03       Impact factor: 1.181

5.  Detergents: an overview.

Authors:  J M Neugebauer
Journal:  Methods Enzymol       Date:  1990       Impact factor: 1.600

6.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

Review 7.  Amoebiasis.

Authors:  Samuel L Stanley
Journal:  Lancet       Date:  2003-03-22       Impact factor: 79.321

8.  Asymmetric modulation of cytosolic cAMP activity induces growth cone turning.

Authors:  A M Lohof; M Quillan; Y Dan; M M Poo
Journal:  J Neurosci       Date:  1992-04       Impact factor: 6.167

Review 9.  Pathogenic and opportunistic free-living amoebae: Acanthamoeba spp., Balamuthia mandrillaris, Naegleria fowleri, and Sappinia diploidea.

Authors:  Govinda S Visvesvara; Hercules Moura; Frederick L Schuster
Journal:  FEMS Immunol Med Microbiol       Date:  2007-04-11

10.  Molecular mechanism of membrane permeabilization by the peptide antibiotic surfactin.

Authors:  Carmen Carrillo; José A Teruel; Francisco J Aranda; Antonio Ortiz
Journal:  Biochim Biophys Acta       Date:  2003-04-01
View more
  3 in total

1.  Cell lysis via acoustically oscillating sharp edges.

Authors:  Zeyu Wang; Po-Hsun Huang; Chuyi Chen; Hunter Bachman; Shuaiguo Zhao; Shujie Yang; Tony J Huang
Journal:  Lab Chip       Date:  2019-11-13       Impact factor: 6.799

Review 2.  Chemical analysis of single cells.

Authors:  Yuqing Lin; Raphaël Trouillon; Gulnara Safina; Andrew G Ewing
Journal:  Anal Chem       Date:  2011-04-28       Impact factor: 6.986

Review 3.  Review of Microfluidic Methods for Cellular Lysis.

Authors:  Emil Grigorov; Boris Kirov; Marin B Marinov; Vassil Galabov
Journal:  Micromachines (Basel)       Date:  2021-04-28       Impact factor: 2.891

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.