Literature DB >> 19966565

Validation of tissue quality parameters for donor corneas designated for emergency use in preservation of the globe.

Wilhelmina J Rijneveld1, Rachel Wolff, Hennie J Völker-Dieben, Elisabeth Pels.   

Abstract

PURPOSE: To validate tissue quality parameters for donor corneas designated for emergency grafting to preserve the globe.
METHODS: In a longitudinal cohort follow-up study, 151 emergency grafts in the Netherlands were studied. Grafts were performed with a pool of organ-cultured donor corneas designated for emergency grafting and prepared for immediate use with all safety tests performed. Assignation criteria were corneas with a small superficial stromal opacity but meeting all selection criteria for penetrating keratoplasty tissue and corneas without stromal opacity but an endothelial cell density from 1800 to 2300 cells per square millimeter or mild polymegethism or pleomorphism. Cox multivariate regression analysis, Kaplan-Meier survival, and log rank test were applied.
RESULTS: All requests for corneal tissue were honored within 24 hours. Ninety-one patients showed a complete and 60 an imminent perforation. One hundred thirty-one penetrating grafts and 20 lamellar grafts have been used. The globes were saved in 140 of the 151 patients (92.7%). Globe preservation was not significantly related to the absence of penetrating keratoplasty quality of the donor endothelium, the type of grafting, the degree of vascularization in the host cornea, or diabetic disease in the recipient. The main risk factor for globe preservation was the presence of a systemic autoimmune disease in the recipient (P = 0.0021).
CONCLUSIONS: A selected pool of donor corneas designated for emergency grafting, that does not interfere with the scheduled procedures, allows more efficient and safe use of donor tissue in case of an imminent perforation. Globe preservation rates justify the quality criteria for designation of this tissue.

Entities:  

Mesh:

Year:  2010        PMID: 19966565     DOI: 10.1097/ICO.0b013e3181ac07bc

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  2 in total

1.  Factors that influence the suitability of human organ-cultured corneas.

Authors:  T Röck; J Hofmann; S Thaler; M Bramkamp; K U Bartz-Schmidt; E Yoeruek; D Röck
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-08-20       Impact factor: 3.117

2.  Use of Fish Scale-Derived BioCornea to Seal Full-Thickness Corneal Perforations in Pig Models.

Authors:  Shih-Cheng Chen; Niklas Telinius; Han-Tse Lin; Min-Chang Huang; Chien-Chen Lin; Cheng-Hung Chou; Jesper Hjortdal
Journal:  PLoS One       Date:  2015-11-24       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.