Literature DB >> 19964890

MRI compatibility evaluation of a piezoelectric actuator system for a neural interventional robot.

Yi Wang1, Gregory A Cole, Hao Su, Julie G Pilitsis, Gregory S Fischer.   

Abstract

The work presented in this paper has been performed in furtherance of developing an MRI-compatible surgical robotic system, specifically targeting the neural intervention procedure for the treatment of Parkinson's Syndrome known as deep brain stimulation (DBS). In this paper we discuss the construction and testing of the MR-compatible controller, sensors and actuators, and the compatibility testing we have done to validate the success of our efforts in eliminating signal interference. Our robotic system was tested on a Phillips Achieva 3 Tesla MRI machine under diagnostic T1 and T2, high speed FGRE and functional EPI imaging protocols. It has been shown to operate without introducing any statistically significant degradation in image quality. We have shown that the creation of an MR-compatible electronically controlled closed-loop robotic actuation system and linkage mechanism can be created successfully within a standard high-field diagnostic magnet with insignificant levels of signal interference.

Entities:  

Mesh:

Year:  2009        PMID: 19964890     DOI: 10.1109/IEMBS.2009.5334206

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  9 in total

1.  Towards a Meso-Scale SMA-Actuated MRI-Compatible Neurosurgical Robot.

Authors:  Mingyen Ho; Alan McMillan; J Marc Simard; Rao Gullapalli; Jaydev P Desai
Journal:  IEEE Trans Robot       Date:  2011-10-10       Impact factor: 5.567

2.  MRI-Safe Robot for Endorectal Prostate Biopsy.

Authors:  Dan Stoianovici; Chunwoo Kim; Govindarajan Srimathveeravalli; Peter Sebrecht; Doru Petrisor; Jonathan Coleman; Stephen B Solomon; Hedvig Hricak
Journal:  IEEE ASME Trans Mechatron       Date:  2013-09-16       Impact factor: 5.303

3.  High-field MRI-compatible needle placement robot for prostate interventions.

Authors:  Hao Su; Alex Camilo; Gregory A Cole; Nobuhiko Hata; Clare M Tempany; Gregory S Fischer
Journal:  Stud Health Technol Inform       Date:  2011

4.  MR Safe Robot, FDA Clearance, Safety and Feasibility Prostate Biopsy Clinical Trial.

Authors:  Dan Stoianovici; Chunwoo Kim; Doru Petrisor; Changhan Jun; Sunghwan Lim; Mark W Ball; Ashley Ross; Katarzyna J Macura; Mohamad Allaf
Journal:  IEEE ASME Trans Mechatron       Date:  2016-10-20       Impact factor: 5.303

5.  Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention.

Authors:  Axel Krieger; Sang-Eun Song; Nathan B Cho; Iulian Iordachita; Peter Guion; Gabor Fichtinger; Louis L Whitcomb
Journal:  IEEE ASME Trans Mechatron       Date:  2011-10-17       Impact factor: 5.303

6.  Robotic Assisted MRI-Guided Interventional Interstitial MR-Guided Focused Ultrasound Ablation in a Swine Model.

Authors:  Jacquelyn MacDonell; Niravkumar Patel; Gregory Fischer; E Clif Burdette; Jiang Qian; Vaibhav Chumbalkar; Goutam Ghoshal; Tamas Heffter; Emery Williams; Matthew Gounis; Robert King; Juliette Thibodeau; Gene Bogdanov; Olivia W Brooks; Erin Langan; Roy Hwang; Julie G Pilitsis
Journal:  Neurosurgery       Date:  2019-05-01       Impact factor: 4.654

7.  Modeling and characterization of shape memory alloy springs with water cooling strategy in a neurosurgical robot.

Authors:  Shing Shin Cheng; Yeongjin Kim; Jaydev P Desai
Journal:  J Intell Mater Syst Struct       Date:  2017-01-24       Impact factor: 2.569

8.  A study on observed ultrasonic motor-induced magnetic resonance imaging (MRI) artifacts.

Authors:  Peyman Shokrollahi; James M Drake; Andrew A Goldenberg
Journal:  Biomed J       Date:  2019-05-06       Impact factor: 4.910

9.  Automated tuning of an eight-channel cardiac transceive array at 7 tesla using piezoelectric actuators.

Authors:  Graeme A Keith; Christopher T Rodgers; Aaron T Hess; Carl J Snyder; J Thomas Vaughan; Matthew D Robson
Journal:  Magn Reson Med       Date:  2014-07-01       Impact factor: 4.668

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.