Literature DB >> 19964249

A preliminary efficacy evaluation performed by opto-electronic plethysmography of asymmetric respiratory rehabilitation.

F Bastianini1, S Silvestri, G Magrone, E Gallotta, S Sterzi.   

Abstract

The aim of present work is to test an optoelectronic system as diagnostic device to preliminary assess the efficacy of asymmetric respiratory rehabilitation. The respiratory rehabilitation efficacy, in terms of tidal volume variations, has been assessed for 14 patients undergone left or right superior lobectomy. Tidal volume variations of six torso compartments have been measured in pre-surgery, post-surgery and post-rehabilitation phases. Significant difference of total chest wall tidal volume has not been observed between the three phases. Tidal volume differences have been observed between paretic and healthy side. Significant tidal volume increase has been observed for non-operated side between pre-surgery and postrehabilitation phases during quiet breathing, mean tidal volume increases of about 32%. Measurement results indicate that respiratory rehabilitation is more effective on non-operated side which, in turn, compensates the operated one. The optoelectronic plethysmograph appears to be a suitable instrument for evaluation of respiratory rehabilitation in case of respiratory volumes asymmetry.

Entities:  

Mesh:

Year:  2009        PMID: 19964249     DOI: 10.1109/IEMBS.2009.5333569

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

1.  Development of a bio-inspired mechatronic chest wall simulator for evaluating the performances of opto-electronic plethysmography.

Authors:  Massaroni C; Schena E; Bastianini F; Scorza A; Saccomandi P; Lupi G; Botta F; Sciuto S A; Silvestri S
Journal:  Open Biomed Eng J       Date:  2014-12-19

2.  Smart Vest for Respiratory Rate Monitoring of COPD Patients Based on Non-Contact Capacitive Sensing.

Authors:  David Naranjo-Hernández; Alejandro Talaminos-Barroso; Javier Reina-Tosina; Laura M Roa; Gerardo Barbarov-Rostan; Pilar Cejudo-Ramos; Eduardo Márquez-Martín; Francisco Ortega-Ruiz
Journal:  Sensors (Basel)       Date:  2018-07-03       Impact factor: 3.576

Review 3.  Assessment of chest wall movement following thoracotomy: a systematic review.

Authors:  Karina Tukanova; Enrica Papi; Sara Jamel; George B Hanna; Alison H McGregor; Sheraz R Markar
Journal:  J Thorac Dis       Date:  2020-03       Impact factor: 3.005

  3 in total