Literature DB >> 19964098

Rapid comprehensive evaluation of luminography and hemodynamic function with 3D radially undersampled phase contrast imaging MRI.

Kevin M Johnson1, Chris Francois, Darren Lum, Thorsten A Bley, Elisabeth Nett, Benjamin Landgraf, Scott B Reeder, Thomas M Grist, Oliver Wieben.   

Abstract

Quantitative flow measurements with volumetric coverage and three directional flow encoding are technically feasible with magnetic resonance imaging yet prohibitively long in clinical settings. Data reconstruction from three dimensional angular undersampled MR acquisitions allows for dramatic reductions in scan time with tolerable imaging artifacts in many clinical applications. This approach provides high spatial resolution suitable for hemodynamic analysis in smaller vessels such as the renal artery, thereby providing additional crucial diagnostic information in a non invasive fashion. In an animal model, transstenotic pressure gradient measurements obtained with the novel acquisition scheme compared favorably with invasive intra arterial measurements (r=0.977; 95% CI: 0.931-0.998; p<0.001). In addition, human studies demonstrate the suitability of the technique for lumen measurements as an alternative for contrast enhanced MR Angiography and the associated risks with the use of an external contrast agent in certain patient populations.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19964098     DOI: 10.1109/IEMBS.2009.5333174

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  3 in total

1.  In vivo three-dimensional MR wall shear stress estimation in ascending aortic dilatation.

Authors:  Erik T Bieging; Alex Frydrychowicz; Andrew Wentland; Benjamin R Landgraf; Kevin M Johnson; Oliver Wieben; Christopher J François
Journal:  J Magn Reson Imaging       Date:  2011-03       Impact factor: 4.813

2.  In vivo validation of 4D flow MRI for assessing the hemodynamics of portal hypertension.

Authors:  Alejandro Roldán-Alzate; Alex Frydrychowicz; Eric Niespodzany; Ben R Landgraf; Kevin M Johnson; Oliver Wieben; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2012-11-12       Impact factor: 4.813

3.  Fast contrast-enhanced 4D MRA and 4D flow MRI using constrained reconstruction (HYPRFlow): potential applications for brain arteriovenous malformations.

Authors:  W Chang; Y Wu; K Johnson; M Loecher; O Wieben; M Edjlali; C Oppenheim; P Roca; J Hald; B Aagaard-Kienitz; D Niemann; C Mistretta; P Turski
Journal:  AJNR Am J Neuroradiol       Date:  2015-02-19       Impact factor: 3.825