Literature DB >> 19963709

Observations of needle-tissue interactions.

Sarthak Misra1, Kyle B Reed, K T Ramesh, Allison M Okamura.   

Abstract

Needles with asymmetric bevel tips naturally bend when they are inserted into soft tissue. In this study, we present an analytical model for the loads developed at the bevel tip during needle-tissue interaction. The model calculates the loads based on the geometry of the bevel edge and gel material properties. The modeled transverse force developed at the tip is compared to forces measured experimentally. The analytical model explains the trends observed in the experiments. In addition to macroscopic studies, we also present microscopic observations of needle-tissue interactions. These results contribute to a mechanics-based model of robotic needle steering, extending previous work on kinematic models.

Entities:  

Mesh:

Year:  2009        PMID: 19963709      PMCID: PMC2859834          DOI: 10.1109/IEMBS.2009.5332872

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  6 in total

1.  Experimental investigation into the deep penetration of soft solids by sharp and blunt punches, with application to the piercing of skin.

Authors:  Oliver A Shergold; Norman A Fleck
Journal:  J Biomech Eng       Date:  2005-10       Impact factor: 2.097

2.  Interactive simulation of needle insertion models.

Authors:  Simon P DiMaio; Septimiu E Salcudean
Journal:  IEEE Trans Biomed Eng       Date:  2005-07       Impact factor: 4.538

Review 3.  Needle insertion into soft tissue: a survey.

Authors:  Niki Abolhassani; Rajni Patel; Mehrdad Moallem
Journal:  Med Eng Phys       Date:  2006-08-28       Impact factor: 2.242

4.  Deflection of a flexible needle during insertion into soft tissue.

Authors:  Niki Abolhassani; Rajni V Patel
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

5.  Modeling of Tool-Tissue Interactions for Computer-Based Surgical Simulation: A Literature Review.

Authors:  Sarthak Misra; K T Ramesh; Allison M Okamura
Journal:  Presence (Camb)       Date:  2008-10-01

6.  Needle-Tissue Interaction Forces for Bevel-Tip Steerable Needles.

Authors:  Sarthak Misra; Kyle B Reed; Andrew S Douglas; K T Ramesh; Allison M Okamura
Journal:  Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron       Date:  2008-10-19
  6 in total
  1 in total

1.  Variable correlation of grid coordinates to core location in template prostate biopsy.

Authors:  Christopher M Brede; Nicholas J Douville; Stephen Jones
Journal:  Curr Urol       Date:  2013-02-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.