Literature DB >> 19961997

Effect of polymerization methods and thermal cycling on color stability of acrylic resin denture teeth.

Wirley Gonçalves Assunção1, Valentim Adelino Ricardo Barão, Murillo Sucena Pita, Marcelo Coelho Goiato.   

Abstract

STATEMENT OF PROBLEM: Acrylic resin denture teeth are widely used due to the chemical bond to the acrylic resin of the denture base. However, discoloration of acrylic resin denture teeth can be a problem.
PURPOSE: The purpose of this study was to investigate the effect of polymerization methods and thermal cycling on the color change of acrylic resin denture teeth.
MATERIAL AND METHODS: Ten different brands of acrylic resin denture teeth were evaluated: Art Plus (AP), Biolux (BX), Biotone IPN (BI), Magister (MG), Mondial 6 (MD), Premium 6 (PR), SR Vivodent PE (SR), Trilux (TR), Trubyte Biotone (TB), and Vipi Dent Plus (VP). Each brand was divided into 2 groups (n=12); each group was subjected to 1 of 2 polymerization methods (microwave, 500 W for 3 minutes, or water bath, 74 degrees C for 9 hours). After polymerization, all of the specimens were thermal cycled between 5 degrees C and 55 degrees C with 30-second dwell times for 5000 cycles. The specimen colors were measured with a spectrophotometer, using the CIE L*a*b* system, at baseline (B), after polymerization (P), and after thermal cycling (T). Color differences (DeltaE) were calculated for periods between P and B (PB), T and B (TB), and T and P (TP). A DeltaE of < or =3.3 was considered clinically acceptable. The data were evaluated by 3-way repeated-measures ANOVA and the Tukey HSD test (alpha=.05).
RESULTS: The highest DeltaE values were obtained for BI and SR teeth; these were significantly higher than the values obtained for the other brands (P<.05). There was no significant difference between the 2 polymerization methods. There was no significant difference between TB and PB for either polymerization method.
CONCLUSIONS: The DeltaE values are within acceptable clinical limits for all brands, for both polymerization methods and different measurement periods.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19961997     DOI: 10.1016/S0022-3913(09)60200-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Effect of cigarette smoke on acrylic resin teeth.

Authors:  Seema S Patil; Dhakshaini M R; Anil Kumar Gujjari
Journal:  J Clin Diagn Res       Date:  2013-09-10

2.  In vitro color change of three dental veneering resins in tea, coffee and tamarind extracts.

Authors:  J K Subramanya; S Muttagi
Journal:  J Dent (Tehran)       Date:  2011-09-30

3.  Effects of thermocycling and various drinks on the color stability of heat-polymerized acrylic resin.

Authors:  Pinar Altinci; Pinar Durkaya
Journal:  J Istanb Univ Fac Dent       Date:  2016-10-01

4.  The Influence of Thermal Curing Cycles on the Color Stability of Unfilled Polymethyl Methacrylate Teeth.

Authors:  Ram Basany; Vinod Bandela; Kulashekar Reddy Nandalur; Dileep Nag Vinnekota; Kiran Kumar Metta; Hari Kumar Mempally; Saraswathi Kanaparthi
Journal:  Cureus       Date:  2022-03-17

5.  Color Stability of Different Denture Teeth Following Immersion in Staining Solutions.

Authors:  Marzieh Ehsani; Leyla Sadighpour; Farideh Geramipanah; Azita Ehsani; Sima Shahabi
Journal:  Front Dent       Date:  2022-02-01

6.  TiO2-Nanofillers Effects on Some Properties of Highly- Impact Resin Using Different Processing Techniques.

Authors:  Hawraa Khalid Aziz
Journal:  Open Dent J       Date:  2018-03-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.