Literature DB >> 19954961

Square wave voltammetry versus electrochemical impedance spectroscopy as a rapid detection technique at electrochemical immunosensors.

Xiaoqiang Liu1, Paul A Duckworth, Danny K Y Wong.   

Abstract

Square wave voltammetry (SWV) was compared to electrochemical impedance spectroscopy (EIS) in developing a label-free electrochemical immunosensor for the hormone estradiol. The immunosensor consists of a Au electrode anchored with a Au nanoparticle|thiolated Protein G-scaffold to facilitate immobilisation of an enhanced quantity of an almost uprightly aligned anti-estradiol capture antibody. Competitive immunoassays between an estradiol-bovine saline albumin complex and free estradiol in a sample were then promoted at the immunosensor. Next, SWV and EIS of [Fe(CN)(6)](3-/4-) were sequentially conducted at the immunosensor. SWV yielded familiar peak-shaped voltammograms with the peak currents readily employable in establishing calibration. A dynamic range up to approximately 1200 pg mL(-1) and a detection limit of 18 pg mL(-1) estradiol were achieved. In EIS, an electron transfer resistance estimated from the Nyquist plots was used in the calibration experiments. A comparable dynamic range up to approximately 1000 pg mL(-1) and a detection limit of 26 pg mL(-1) estradiol were obtained. However, a significantly 10 times longer analysis time and substantial effort were required to complete the EIS determinations relative to SWV. Moreover, a large amount of EIS data involving phase angle was collected but ignored because they would not contribute any useful information to quantitative determination. Overall, SWV was determined to be a more rapid, efficient, effective and low cost detection technique than EIS at label-free electrochemical immunosensors. Copyright 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19954961     DOI: 10.1016/j.bios.2009.10.047

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  Gold nanoparticles in chemical and biological sensing.

Authors:  Krishnendu Saha; Sarit S Agasti; Chaekyu Kim; Xiaoning Li; Vincent M Rotello
Journal:  Chem Rev       Date:  2012-02-02       Impact factor: 60.622

Review 2.  Lectins, Interconnecting Proteins with Biotechnological/Pharmacological and Therapeutic Applications.

Authors:  Luana Cassandra Breitenbach Barroso Coelho; Priscila Marcelino Dos Santos Silva; Vera Lúcia de Menezes Lima; Emmanuel Viana Pontual; Patrícia Maria Guedes Paiva; Thiago Henrique Napoleão; Maria Tereza Dos Santos Correia
Journal:  Evid Based Complement Alternat Med       Date:  2017-03-07       Impact factor: 2.629

3.  Open Source Software for the Real-Time Control, Processing, and Visualization of High-Volume Electrochemical Data.

Authors:  Samuel D Curtis; Kyle L Ploense; Martin Kurnik; Gabriel Ortega; Claudio Parolo; Tod E Kippin; Kevin W Plaxco; Netzahualcóyotl Arroyo-Currás
Journal:  Anal Chem       Date:  2019-09-10       Impact factor: 6.986

4.  Novel and simple electrochemical biosensor monitoring attomolar levels of miRNA-155 in breast cancer.

Authors:  Ana R Cardoso; Felismina T C Moreira; Rúben Fernandes; M Goreti F Sales
Journal:  Biosens Bioelectron       Date:  2016-02-14       Impact factor: 10.618

Review 5.  Comparison of Electrochemical Immunosensors and Aptasensors for Detection of Small Organic Molecules in Environment, Food Safety, Clinical and Public Security.

Authors:  Benoit Piro; Shihui Shi; Steeve Reisberg; Vincent Noël; Guillaume Anquetin
Journal:  Biosensors (Basel)       Date:  2016-02-29

6.  Gold nanoparticles covalently assembled onto vesicle structures as possible biosensing platform.

Authors:  M Fátima Barroso; M Alejandra Luna; Juan S Flores Tabares; Cristina Delerue-Matos; N Mariano Correa; Fernando Moyano; Patricia G Molina
Journal:  Beilstein J Nanotechnol       Date:  2016-05-02       Impact factor: 3.649

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.