Literature DB >> 19945286

Late recurrent hemarthrosis following knee arthroplasty associated with epithelioid angiosarcoma of bone.

M Drexler1, O Dolkart, E Amar, T Pritsch, S Dekel.   

Abstract

We report a case of recurrent hemarthrosis 1 year following total knee arthroplasty in a patient with no bleeding diathesis, the hemarthrosis was found to be related to, and led to the diagnosis of high grade sarcoma of the proximal tibia. Twenty five years earlier, he sustained a lateral tibial plateau fracture and was treated with open reduction and plating. Sarcoma developing in association with a metallic orthopedic prosthesis or hardware is an uncommon, but well-recognized complication. Sarcomas that occur adjacent to orthopaedic prostheses or hardware are of varied types, but are usually osteosarcoma or malignant fibrous histiocytoma. Copyright 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19945286     DOI: 10.1016/j.knee.2009.10.010

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  6 in total

1.  Skeletal sarcoma on the site of retained war bullet fragments and a literature review on long-term complications of retained war shells.

Authors:  Mohammad H Ebrahimzadeh; Ehsan Vahedi; Rashid Ganji; Shahram Bozorgnia
Journal:  Arch Bone Jt Surg       Date:  2013-12-15

Review 2.  Angiosarcoma around total hip arthroplasty: case series and review of the literature.

Authors:  S Terrando; A Sambri; G Bianchi; L Cevolani; L Foschi; E Gozzi; G Pignatti; D M Donati
Journal:  Musculoskelet Surg       Date:  2017-07-24

3.  Recurrent Hemarthroses After TKA Treated With an Intraarticular Injection of Yttrium-90.

Authors:  Stephen Fine; Alex Klestov
Journal:  Clin Orthop Relat Res       Date:  2015-02-25       Impact factor: 4.176

4.  Geniculate artery embolization for recurrent postarthroplasty hemarthrosis of the knee.

Authors:  Moses Azubuike; Ryan Mikus; Poyan Rafiei
Journal:  Radiol Case Rep       Date:  2016-02-17

5.  Angiosarcoma around Hip Joint Prosthesis.

Authors:  Wei Zhu; Bin Feng; Qi Ma; Yu-Long Li; Xi-Tao Song; Xi-Sheng Weng
Journal:  Chin Med J (Engl)       Date:  2016-11-05       Impact factor: 2.628

6.  Right femoral pathological fracture caused by primary bone epithelioid angiosarcoma: Case report.

Authors:  Yatong Li; Xiongfei Zou; Xiaoyan Chang; Xiao Chang; Shengfang Sun; Baozhong Zhang
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.