New technologies for the assessment of breast surgical outcomes.

Giuseppe Catanuto1, Paolo Patete, Andrea Spano, Angela Pennati, Guido Baroni, Maurizio B Nava.   

Abstract

BACKGROUND: Although interest in objective and quantitative breast surgical outcome assessment is rapidly increasing, published reports have yet to make a real impact on everyday clinical practice.
OBJECTIVE: The authors offer a preliminary report on an innovative methodology customized for breast shape evaluation that, in our opinion, could overcome most of the technical and conceptual limitations of previous studies.
METHODS: Three-dimensional/four-dimensional breast scanning was performed using a breast-dedicated prototype laser scanner made up of a handheld device, including a charge-coupled device (CCD) camera coupled to a spot laser source. Two additional motion analyzer cameras were used for handheld device tracking and the acquisition of patient motion.
RESULTS: Seven female volunteers, including both subjects who had undergone cosmetic or reconstructive breast surgery and those with no such history, underwent a dynamic breast shape survey. Curvature mapping on three-dimensional mesh warranted precise measurements of local geometric properties of the breast surface. Elaboration and representation of breast dynamic behavior during common motor tasks (eg, walking, running, sitting, and lying) was also possible.
CONCLUSIONS: The scanning methodology reported here reliably describes the breast surface not only in a static position, but also at specific postures or during motion of the body. It also opens the door for quantitative static and dynamic assessment of surgical outcomes, the intraoperative assessment of breast shape, and other applications. Limitations include the relatively long amount of time required for each scan and the need for technical and clinical validation, particularly with respect to four-dimensional assessment.

Entities:  

Mesh:

Year:  2009        PMID: 19944995     DOI: 10.1016/j.asj.2009.09.004

Source DB:  PubMed          Journal:  Aesthet Surg J        ISSN: 1090-820X            Impact factor:   4.283


  3 in total

1.  The need for a standardised anthropometric protocol for objective assessment of pre- and postoperative breast surgery.

Authors:  Nicola Brown; Joanna Scurr
Journal:  Gland Surg       Date:  2012-11

Review 2.  The current progress and critical analysis of three-dimensional scanning and three-dimensional printing applications in breast surgery.

Authors:  S A Alshehri; S K Singh; A Mosahebi; D M Kalaskar
Journal:  BJS Open       Date:  2021-05-07

3.  A prospective study of breast dynamic morphological changes after dual-plane augmentation mammaplasty with 3D scanning technique.

Authors:  Kai Ji; Jie Luan; Chunjun Liu; Dali Mu; Lanhua Mu; Minqiang Xin; Jingjing Sun; Shilu Yin; Lin Chen
Journal:  PLoS One       Date:  2014-03-26       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.