Literature DB >> 19942187

The effect of an ankle-foot orthosis on temporal spatial parameters and asymmetry of gait in hemiparetic patients.

Alberto Esquenazi1, Demet Ofluoglu, Barbara Hirai, Stella Kim.   

Abstract

OBJECTIVE: To investigate the effect of an ankle-foot orthosis (AFO) on certain walking parameters in patients with hemiplegia.
DESIGN: Retrospective study.
SETTING: Gait and Motion Analysis Laboratory at MossRehab. PARTICIPANTS: A total of 1150 records of patients with stroke who were referred to the Gait and Motion Analysis Laboratory between 2000 and 2008 for an evaluation of their walking. Of this group, 217 patients wore braces at the time of the gait evaluation and were selected for a more in-depth review. Among these patients, 42 records were selected because of the existence of available data from temporal spatial analysis meeting 2 conditions: walking with bare feet and walking with an AFO during the same visit. METHODS AND MAIN OUTCOME MEASUREMENTS: Under both conditions, temporal spatial parameters of gait, including self-selected velocity, cadence, stance time, swing time, double support time, step length, and width of the base of support, were assessed by the use of an electronic gait mat (Gait Mat II, EQ Inc.) originally designed in the Moss Rehabilitation Engineering Center.
RESULTS: Walking velocity, cadence, percent stance, double support, and step length significantly increased, whereas affected side percent swing and width of the base of support decreased when patients used an AFO. Symmetries of stance time (P = .0001) and step length (P = .002) improved as well when patients used an AFO compared with walking barefoot.
CONCLUSION: In this sample of patients with stroke, the use of an AFO improved the symmetry of several of the temporal spatial parameters of gait, and consequently, the gait pattern of these hemiparetic patients was enhanced.

Entities:  

Mesh:

Year:  2009        PMID: 19942187     DOI: 10.1016/j.pmrj.2009.09.012

Source DB:  PubMed          Journal:  PM R        ISSN: 1934-1482            Impact factor:   2.298


  13 in total

1.  Restoring mobility after stroke: first kinematic results from a pilot study with a hybrid drop foot stimulator.

Authors:  D Yao; E Jakubowitz; K Tecante; M Lahner; S Ettinger; L Claassen; C Plaass; C Stukenborg-Colsman; K Daniilidis
Journal:  Musculoskelet Surg       Date:  2016-09-01

Review 2.  Gait disorder rehabilitation using vision and non-vision based sensors: a systematic review.

Authors:  Asraf Ali; Kenneth Sundaraj; Badlishah Ahmad; Nizam Ahamed; Anamul Islam
Journal:  Bosn J Basic Med Sci       Date:  2012-08       Impact factor: 3.363

3.  Subjective outcome following neurostimulator implantation as drop foot therapy due to lesions in the central nervous system-midterm results.

Authors:  D Yao; C Stukenborg-Colsman; S Ettinger; L Claassen; C Plaass; N Martinelli; K Daniilidis
Journal:  Musculoskelet Surg       Date:  2019-05-03

4.  Spatiotemporal, kinematic, and kinetic effects of a peroneal nerve stimulator versus an ankle foot orthosis in hemiparetic gait.

Authors:  Lynne R Sheffler; Stephanie Nogan Bailey; Richard D Wilson; John Chae
Journal:  Neurorehabil Neural Repair       Date:  2012-11-27       Impact factor: 3.919

5.  Effect of ankle foot orthosis on gait parameters and functional ambulation in patients with stroke.

Authors:  Serdar Kesikburun; Ferdi Yavuz; Ümüt Güzelküçük; Evren Yaşar; Birol Balaban
Journal:  Turk J Phys Med Rehabil       Date:  2017-06-03

6.  Effects of the ankle angle of an ankle foot orthosis on foot pressure during the gait in healthy adults.

Authors:  Jong-Sung Chang; Hae-Yong Lee; Myoung-Kwon Kim
Journal:  J Phys Ther Sci       Date:  2015-04-30

Review 7.  Effect of Ankle-foot Orthosis on Gait Velocity and Cadence of Stroke Patients: A Systematic Review.

Authors:  Luiz Alfredo Braun Ferreira; Hugo Pasini Neto; Luanda André College Grecco; Thaluanna Calil Lourenço Christovão; Natália Almeidacarvalho Duarte; Roberta Delasta Lazzari; Manuela Galli; Claudia Santos Oliveira
Journal:  J Phys Ther Sci       Date:  2013-12-11

8.  Changes in angular kinematics of the paretic lower limb at different orthotic angles of plantar flexion limitation of an ankle-foot-orthosis for stroke patients.

Authors:  Hye Young Lee; Jeon Hyeong Lee; Kyoung Kim
Journal:  J Phys Ther Sci       Date:  2015-03-31

9.  Effect of Ankle-foot Orthosis on Lower Limb Muscle Activities and Static Balance of Stroke Patients Authors' Names.

Authors:  Youngmin Lee; Jin Gang Her; Youngeun Choi; Heesoo Kim
Journal:  J Phys Ther Sci       Date:  2014-02-28

10.  The influence of an ankle-foot orthosis on the spatiotemporal gait parameters and functional balance in chronic stroke patients.

Authors:  Vendula Bouchalová; Els Houben; Dorine Tancsik; Lotte Schaekers; Leni Meuws; Peter Feys
Journal:  J Phys Ther Sci       Date:  2016-05-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.