Literature DB >> 19940337

High performance liquid chromatography/negative ion electrospray tandem mass spectrometry method for the measurement of hydrochlorothiazide in human plasma: application to a comparative bioavailability study.

Damaramadugu Rajasekhar1, Inamadugu Jaswanth Kumara, Ponneri Venkateswarlu.   

Abstract

A sensitive, selective and rapid liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of hydrochlorothiazide (HCTZ) in human plasma. The plasma samples were prepared by solid phase extraction using Oasis HLB 30 mg 1CC cartridges. Chromatographic separation was accomplished on a Thermo Hypurity Advance (50 mm x 4.6mm i.d., 5 microm) column. The mobile phase consisted of HPLC Grade Acetonitrile: 2 mM Ammonium acetate (90 : 10 v / v) at a flow rate of 0.5 mL min(-1). Detection of hydrochlorothiazide and the internal standard (IS) zidovudine was achieved by ESI MS/MS in the negative ion mode. The total chromatographic runtime was 2.5 minutes. The linear range of the method was from 2.036-203.621 ng mL(-1). The mass transition ion pair has been followed as m/z 296.10/205.00 for HCTZ and 266.10/223.10 for Zidovudine. The mean overall recovery of HCTZ was 66.40% with a precision of 2.44%. The mean recovery of internal standard (Zidovudine) was 63.62% with a precision ranging from 2.06% to 5.40%. The method was successfully applied for the evaluation of pharmacokinetics of hydrochlorothiazide after single oral dose of 25 mg hydrochlorothiazide to healthy volunteers.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19940337     DOI: 10.1255/ejms.1038

Source DB:  PubMed          Journal:  Eur J Mass Spectrom (Chichester)        ISSN: 1469-0667            Impact factor:   1.067


  4 in total

1.  Fast and sensitive LC-MS/MS method for the simultaneous determination of lisinopril and hydrochlorothiazide in human plasma.

Authors:  Jaivik V Shah; Priyanka A Shah; Priya V Shah; Mallika Sanyal; Pranav S Shrivastav
Journal:  J Pharm Anal       Date:  2016-11-25

2.  Application of an LC-MS/MS method for the analysis of amlodipine, valsartan and hydrochlorothiazide in polypill for a bioequivalence study.

Authors:  Jaivik V Shah; Jignesh M Parekh; Priyanka A Shah; Priya V Shah; Mallika Sanyal; Pranav S Shrivastav
Journal:  J Pharm Anal       Date:  2017-06-04

3.  Simultaneous quantification of amiloride and hydrochlorothiazide in human plasma by liquid chromatography-tandem mass spectrometry.

Authors:  Jaivik V Shah; Priyanka A Shah; Mallika Sanyal; Pranav S Shrivastav
Journal:  J Pharm Anal       Date:  2017-03-24

4.  Method Validation for Simultaneous Quantification of Olmesartan and Hydrochlorothiazide in Human Plasma Using LC-MS/MS and Its Application Through Bioequivalence Study in Healthy Volunteers.

Authors:  Arvind Kumar; Surya Prakash Dwivedi; Tulika Prasad
Journal:  Front Pharmacol       Date:  2019-07-23       Impact factor: 5.810

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.