Literature DB >> 19938066

Mimic of a large-scale diafiltration process by using ultra scale-down rotating disc filter.

Guijun Ma1, Jean Aucamp, Spyridon Gerontas, Ranna Eardley-Patel, Alan Craig, Mike Hoare, Yuhong Zhou.   

Abstract

Ultra scale-down (USD) approach is a powerful tool to predict large-scale process performance by using very small amounts of material. In this article, we present a method to mimic flux and transmission performance in a labscale crossflow operation by an USD rotating disc filter (RDF). The Pellicon 2 labscale system used for evaluation of the mimic can readily be related to small pilot and industrial scale. Adopted from the pulsed sample injection technique by Ghosh and Cui (J Membr Sci. 2000;175:5-84), the RDF has been modified by building in inserts to allow the flexibility of the chamber volume, so that only 1.5 mL of processing material is required for each diafiltration experiment. The reported method enjoys the simplicity of dead-end mode operation with accurate control of operation conditions that can mimic well the crossflow operation in large scale. Wall shear rate correlations have been established for both the labscale cassette and the USD device, and a mimic has been developed by operating both scales under conditions with equivalent averaged shear rates. The studies using E. coli lysate show that the flux vs. transmembrane pressure profile follows a first-order model, and the transmission of antibody fragment (Fab') is independent of transmembrane pressure. Predicted flux and transmission data agreed well with the experimental results of a labscale diafiltration where the cassette resistance was considered.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19938066     DOI: 10.1002/btpr.327

Source DB:  PubMed          Journal:  Biotechnol Prog        ISSN: 1520-6033


  3 in total

1.  An ultra scale-down methodology to characterize aspects of the response of human cells to processing by membrane separation operations.

Authors:  Maria Fernanda Masri; Kate Lawrence; Ivan Wall; Michael Hoare
Journal:  Biotechnol Bioeng       Date:  2017-02-23       Impact factor: 4.530

2.  An ultra scale-down method to investigate monoclonal antibody processing during tangential flow filtration using ultrafiltration membranes.

Authors:  Lara Fernandez-Cerezo; Andrea C M E Rayat; Alex Chatel; Jennifer M Pollard; Gary J Lye; Michael Hoare
Journal:  Biotechnol Bioeng       Date:  2019-01-04       Impact factor: 4.530

3.  Ultra scale-down characterization of the impact of conditioning methods for harvested cell broths on clarification by continuous centrifugation-Recovery of domain antibodies from rec E. coli.

Authors:  Alex Chatel; Peter Kumpalume; Mike Hoare
Journal:  Biotechnol Bioeng       Date:  2013-12-28       Impact factor: 4.530

  3 in total