Literature DB >> 19937776

Comparison of 2-year clinical outcomes with sirolimus and paclitaxel-eluting stents for patients with diabetes: results of the Registro Regionale AngiopLastiche Emilia-Romagna Registry.

Marco Balducelli1, Paolo Ortolani, Paolo Marzaroli, Giancarlo Piovaccari, Alberto Menozzi, Antonio Manari, Pietro Sangiorgio, Fabio Tarantino, Rosario Rossi, Aleardo Maresta, Stefano Tondi, Francesco Passerini, Paolo Guastaroba, Roberto Grilli, Antonio Marzocchi.   

Abstract

BACKGROUND: Long-term outcomes of percutaneous coronary interventions (PCI) with sirolimus-eluting stents (SES) compared to paclitaxel-eluting-stents (PES) in unselected diabetics in routine practice is still debated.
OBJECTIVE: This study compared the 2-year incidence of MACE (all-cause mortality, nonfatal myocardial infarction and target vessel revascularization) of SES and PES in a real-world setting of patients with diabetes.
DESIGN: Observational, multicenter, nonrandomized study.
SETTING: Prospective web-based registry (REAL Registry; study period, 2002-2005) comprising all 13 hospitals performing PCI. PATIENTS: Among the 945 eligible patients treated with either SES alone (n = 606) or PES alone (n = 339), 29% were insulin-requiring, 72% had multivessel coronary disease, 26% had prior myocardial infarction and 10% had poor left ventricular function. MEASUREMENTS: Unadjusted and propensity score-adjusted 2-year clinical outcome.
RESULTS: After propensity score adjustment, 2-year MACE incidence in the SES and PES groups was equivalent (23.3% vs. 23.7%, HR 1.01, 95%CI 0.72-1.42, P = 0.96). Adjusted 2-year angiographic stent thrombosis occurred in 1.1% of the SES patients versus 2.6% of the PES patients (P = 0.15). In this large, real-world, diabetic population treated with DES, there was no difference in outcome between SES and PES. Further studies are needed to demonstrate the long-term safety of different types of DES in patients with diabetes.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19937776     DOI: 10.1002/ccd.22293

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  1 in total

Review 1.  Stent thrombosis and adverse cardiovascular outcomes observed between six months and five years with sirolimus-eluting stents and other drug-eluting stents in patients with Type 2 diabetes mellitus complicated by coronary artery disease: A systematic review and meta-analysis.

Authors:  Pravesh Kumar Bundhun; M Zafooruddin Sani Soogund; Manish Pursun; Meng-Hua Chen
Journal:  Medicine (Baltimore)       Date:  2016-07       Impact factor: 1.889

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.