Literature DB >> 1993588

A reproducible method for injecting the mouse corneal stroma.

R L Hendricks1, R J Epstein, M A Viana, D A Hoffmann.   

Abstract

An improved delivery system for injecting the mouse corneal stroma was developed. This system incorporates the following features: a repeating dispenser that eliminates inaccuracies in depressing a syringe plunger, foot activation which frees both hands for manipulating the needle and permits constant observation of the injection site, and a flexible 30-cm, 32-gauge stainless steel needle with a 30 degrees bevel and a locking hub that resists pulsation due to back pressure while permitting freedom of motion by the operator. These injections were done while observing the cornea with a vertically mounted slit lamp, ideally suited for examining and photographing the eyes of laboratory animals. The reproducibility of the new delivery system, expressed in terms of the signal-to-noise ratio, was estimated and compared with that of a hand-held microsyringe by injecting a solution of radioactive chromium into the corneal stroma of A/J mice. The eyes were removed within 1 hr of injection, and the amount of chromium in each eye was determined in a gamma counter. The new delivery system had significantly (P less than 0.05) greater reproducibility than the hand-held syringe and could be calibrated to deliver up to 0.65 microliter to the mouse cornea.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1993588

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  4 in total

1.  Gene transfer of interleukin 10 to the murine cornea using electroporation.

Authors:  Rui Zhou; David A Dean
Journal:  Exp Biol Med (Maywood)       Date:  2007-03

2.  Systematic assessment of microneedle injection into the mouse cornea.

Authors:  Mario Matthaei; Huan Meng; Imran Bhutto; Qingguo Xu; Edwin Boelke; Justin Hanes; Albert S Jun
Journal:  Eur J Med Res       Date:  2012-06-20       Impact factor: 2.175

3.  Tacrolimus (FK506) suppresses TREM-1 expression at an early but not at a late stage in a murine model of fungal keratitis.

Authors:  Weilan Huang; Shiqi Ling; Xiuhua Jia; Binwu Lin; Xi Huang; Jing Zhong; Weihua Li; Xiaolei Lin; Yifang Sun; Jin Yuan
Journal:  PLoS One       Date:  2014-12-02       Impact factor: 3.240

4.  A novel, tomographic imaging probe for rapid diagnosis of fungal keratitis.

Authors:  Min Hee Lee; Gregory Wiedman; Steven Park; Arkady Mustaev; Yanan Zhao; David S Perlin
Journal:  Med Mycol       Date:  2018-10-01       Impact factor: 4.076

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.