Literature DB >> 19934509

A single chamber packed bed microbial fuel cell biosensor for measuring organic content of wastewater.

Mirella Di Lorenzo1, Tom P Curtis, Ian M Head, Sharon B Velasquez-Orta, Sharon B Velasquez-Orta, Keith Scott.   

Abstract

This study reports an investigation of the effect of the anode surface area on the performance of a single chamber microbial fuel cell (SCMFC) based biosensor for measuring the organic content of wastewater. A packed bed of graphite granules was used as the anode. The surface area of the anode was changed by altering the granule bed thickness (0.3 cm and 1 cm). The anode surface area was found to play a role in the dynamic response of the system. For a granule bed thickness of 1 cm and with an external resistance of 500 Omega, the response time (defined as the time required to achieve 95% of the steady-state current) was reduced by approximately 65% in comparison to a SCMFC biosensor with a carbon cloth anode.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19934509     DOI: 10.2166/wst.2009.699

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  2 in total

1.  Redox Potential Heterogeneity in Fixed-Bed Electrodes Leads to Microbial Stratification and Inhomogeneous Performance.

Authors:  Jose Rodrigo Quejigo; Benjamin Korth; Anne Kuchenbuch; Falk Harnisch
Journal:  ChemSusChem       Date:  2021-01-19       Impact factor: 8.928

Review 2.  Microbial fuel cells for in-field water quality monitoring.

Authors:  Lola Gonzalez Olias; Mirella Di Lorenzo
Journal:  RSC Adv       Date:  2021-05-04       Impact factor: 4.036

  2 in total