Experimental verification of a commercial Monte Carlo-based dose calculation module for high-energy photon beams.

Thomas Künzler1, Irina Fotina, Markus Stock, Dietmar Georg.   

Abstract

The dosimetric performance of a Monte Carlo algorithm as implemented in a commercial treatment planning system (iPlan, BrainLAB) was investigated. After commissioning and basic beam data tests in homogenous phantoms, a variety of single regular beams and clinical field arrangements were tested in heterogeneous conditions (conformal therapy, arc therapy and intensity-modulated radiotherapy including simultaneous integrated boosts). More specifically, a cork phantom containing a concave-shaped target was designed to challenge the Monte Carlo algorithm in more complex treatment cases. All test irradiations were performed on an Elekta linac providing 6, 10 and 18 MV photon beams. Absolute and relative dose measurements were performed with ion chambers and near tissue equivalent radiochromic films which were placed within a transverse plane of the cork phantom. For simple fields, a 1D gamma (gamma) procedure with a 2% dose difference and a 2 mm distance to agreement (DTA) was applied to depth dose curves, as well as to inplane and crossplane profiles. The average gamma value was 0.21 for all energies of simple test cases. For depth dose curves in asymmetric beams similar gamma results as for symmetric beams were obtained. Simple regular fields showed excellent absolute dosimetric agreement to measurement values with a dose difference of 0.1% +/- 0.9% (1 standard deviation) at the dose prescription point. A more detailed analysis at tissue interfaces revealed dose discrepancies of 2.9% for an 18 MV energy 10 x 10 cm(2) field at the first density interface from tissue to lung equivalent material. Small fields (2 x 2 cm(2)) have their largest discrepancy in the re-build-up at the second interface (from lung to tissue equivalent material), with a local dose difference of about 9% and a DTA of 1.1 mm for 18 MV. Conformal field arrangements, arc therapy, as well as IMRT beams and simultaneous integrated boosts were in good agreement with absolute dose measurements in the heterogeneous phantom. For the clinical test cases, the average dose discrepancy was 0.5% +/- 1.1%. Relative dose investigations of the transverse plane for clinical beam arrangements were performed with a 2D gamma-evaluation procedure. For 3% dose difference and 3 mm DTA criteria, the average value for gamma(>1) was 4.7% +/- 3.7%, the average gamma(1%) value was 1.19 +/- 0.16 and the mean 2D gamma-value was 0.44 +/- 0.07 in the heterogeneous phantom. The iPlan MC algorithm leads to accurate dosimetric results under clinical test conditions.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19934489     DOI: 10.1088/0031-9155/54/24/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  Four-dimensional dosimetry validation and study in lung radiotherapy using deformable image registration and Monte Carlo techniques.

Authors:  Tzung-Chi Huang; Ji-An Liang; Thomas Dilling; Tung-Hsin Wu; Geoffrey Zhang
Journal:  Radiat Oncol       Date:  2010-05-29       Impact factor: 3.481

2.  Dosimetric evaluation of abdominal compression as a method to reduce the incidence of radiation-induced pneumonitis in lung SBRT treatment.

Authors:  Vikren Sarkar; Long Huang; Yu-Huei Jessica Huang; Martin W Szegedi; Prema Rassiah-Szegedi; Hui Zhao; Ying J Hitchcock; Kristine E Kokeny; Brian Wang; Bill J Salter
Journal:  J Radiosurg SBRT       Date:  2016

3.  CT-myelography for high-dose irradiation of spinal and paraspinal tumors with helical tomotherapy: revival of an old tool.

Authors:  Matthias Uhl; Florian Sterzing; Gregor Habl; Kai Schubert; Gabriele Sroka-Perez; Jürgen Debus; Klaus Herfarth
Journal:  Strahlenther Onkol       Date:  2011-06-27       Impact factor: 3.621

4.  Dose calculation accuracy in particle therapy: Comparing carbon ions with protons.

Authors:  Sirinya Ruangchan; Hugo Palmans; Barbara Knäusl; Dietmar Georg; Monika Clausen
Journal:  Med Phys       Date:  2021-09-23       Impact factor: 4.506

5.  Evaluation of 4D dose to a moving target with Monte Carlo dose calculation in stereotactic body radiotherapy for lung cancer.

Authors:  Kiyotomo Matsugi; Mitsuhiro Nakamura; Yuki Miyabe; Chikako Yamauchi; Yukinori Matsuo; Takashi Mizowaki; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2012-12-18

6.  The significance of PTV dose coverage on cancer control outcomes in early stage non-small cell lung cancer patients treated with highly ablative stereotactic body radiation therapy.

Authors:  Narek Shaverdian; Stephen Tenn; Darlene Veruttipong; Jason Wang; John Hegde; Chul Lee; Minsong Cao; Nzhde Agazaryan; Michael Steinberg; Patrick Kupelian; Percy Lee
Journal:  Br J Radiol       Date:  2016-01-14       Impact factor: 3.039

7.  Evaluation of dose prediction error and optimization convergence error in four-dimensional inverse planning of robotic stereotactic lung radiotherapy.

Authors:  Mark K H Chan; Dora L W Kwong; Anthony Tong; Eric Tam; Sherry C Y Ng
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

8.  Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT.

Authors:  Han Liu; Tingliang Zhuang; Kevin Stephans; Gregory Videtic; Stephen Raithel; Toufik Djemil; Ping Xia
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

9.  Practical methods for improving dose distributions in Monte Carlo-based IMRT planning of lung wall-seated tumors treated with SBRT.

Authors:  Michael B Altman; Jian-Yue Jin; Sangroh Kim; Ning Wen; Dezhi Liu; M Salim Siddiqui; Munther I Ajlouni; Benjamin Movsas; Indrin J Chetty
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

10.  A quantitative comparison of the performance of three deformable registration algorithms in radiotherapy.

Authors:  Daniella Fabri; Valentina Zambrano; Amon Bhatia; Hugo Furtado; Helmar Bergmann; Markus Stock; Christoph Bloch; Carola Lütgendorf-Caucig; Supriyanto Pawiro; Dietmar Georg; Wolfgang Birkfellner; Michael Figl
Journal:  Z Med Phys       Date:  2013-08-19       Impact factor: 4.820

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.