Literature DB >> 19933643

Amplatzer septal occluder closure of atrial septal defect: evaluation of transthoracic echocardiography, cardiac CT, and transesophageal echocardiography.

Sheung-Fat Ko1, Chi-Di Liang, Hon-Kan Yip, Chung-Cheng Huang, Shu-Hang Ng, Chien-Fu Huang, Min-Chi Chen.   

Abstract

OBJECTIVE: The purpose of this study was to compare transthoracic echocardiography (TTE), cardiac CT, and transesophageal echocardiography (TEE) in the evaluation of secundum atrial septal defect (ASD) for closure with an Amplatzer septal occluder in pediatric patients. SUBJECTS AND METHODS: The cases of 28 children with ASD initially diagnosed with TTE who were scheduled for cardiac CT for evaluation for insertion of an Amplatzer septal occluder under TEE guidance were reviewed. The patients were divided into a group with small ASD (long axis < 1.5 cm) and a group with large ASD (long axis > or = 1.5 cm). Measurements of the ASD obtained at TTE, cardiac CT, and TEE were compared. Kappa statistics were used to correlate the diagnostic value of cardiac CT assessed by two independent reviewers.
RESULTS: After cardiac CT, six patients were excluded from occluder implantation; therefore, 22 patients (seven boys, 15 girls; mean age, 4.95 years; range, 2-11 years) were included in the study. There were no significant differences in the ages and sexes of the patients in the two groups, but pulmonary-to-systemic blood flow ratio in the large-ASD group was significantly greater than that in the small-ASD group (3.54 +/- 1.43 vs 1.89 +/- 0.36; p = 0.001). With respect to long- and short-axis lengths of the ASD, interatrial septum, and four rims and to detection of rim deficiency, neither group had a significant difference between cardiac CT findings at ventricular end-systole and TEE findings. The long axis of the ASD in the large-ASD group measured at cardiac CT at end-systole and TEE was significantly longer than the long axis measured at TTE (p = 0.012). A high diagnostic score with good interobserver correlation (kappa = 0.674-0.750) validated the feasibility of cardiac CT in the assessment of ASD for closure with an Amplatzer septal occluder.
CONCLUSION: The long axis of a large ASD can be underestimated at TTE. Cardiac CT seems comparable with TEE in the assessment of ASD and is helpful in noninvasive evaluation for Amplatzer septal occluder implantation, especially for large ASD.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19933643     DOI: 10.2214/AJR.09.2854

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  14 in total

1.  Intraoperative device closure of atrial septal defects in the older population.

Authors:  Hui Zhang; Qiang Chen; Liang-Wan Chen; Hua Cao; Gui-Can Zhang; Dao-Zhong Chen
Journal:  J Cardiothorac Surg       Date:  2011-09-29       Impact factor: 1.637

2.  Preoperative cardiac computed tomography for demonstration of congenital cardiac septal defect in adults.

Authors:  Hye-Joung Eom; Dong Hyun Yang; Joon-Won Kang; Dae-Hee Kim; Jong-Min Song; Duk-Hyun Kang; Jae-Kwan Song; Joon Bum Kim; Sung-Ho Jung; Suk Jung Choo; Cheol Hyun Chung; Jae Won Lee; Tae-Hwan Lim
Journal:  Eur Radiol       Date:  2014-12-18       Impact factor: 5.315

3.  Ring array transducers for real-time 3-D imaging of an atrial septal occluder.

Authors:  Edward D Light; Brooks D Lindsey; Joseph A Upchurch; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2012-06-12       Impact factor: 2.998

4.  Subacute, silent embolization of amplatzer atrial septal defect closure device to the pulmonary artery.

Authors:  Jang-Won Son; Jong-Seon Park
Journal:  J Cardiovasc Ultrasound       Date:  2012-12-31

5.  Computed Tomography for Structural Heart Disease and Interventions.

Authors:  Pascal Thériault-Lauzier; Marco Spaziano; Beatriz Vaquerizo; Jean Buithieu; Giuseppe Martucci; Nicolo Piazza
Journal:  Interv Cardiol       Date:  2015-09

6.  Transcatheter Device Closure of Secundum Atrial Septal Defect in Adult Patient.

Authors:  Nabil Naser; Nura Hadziomerovic; Sevleta Avdic
Journal:  Acta Inform Med       Date:  2021-03

7.  Transcatheter closure of multiple atrial septal defects with the amplatzer device.

Authors:  Mi Jin Cho; Jinyoung Song; Soo Jin Kim; Eun Young Choi; Sang Yoon Lee; Woo Seup Shim
Journal:  Korean Circ J       Date:  2011-09-29       Impact factor: 3.243

8.  Balloon occlusive diameter of non-circular atrial septal defects in transcatheter closure with amplatzer septal occluder.

Authors:  Kwang Hoon Kim; Jinyoung Song; I-Seok Kang; Sung-A Chang; June Huh; Seung Woo Park
Journal:  Korean Circ J       Date:  2013-10-30       Impact factor: 3.243

9.  The role of computed tomography in pre-procedural planning of cardiovascular surgery and intervention.

Authors:  Prabhakar Rajiah; Paul Schoenhagen
Journal:  Insights Imaging       Date:  2013-08-02

10.  Outcome of transcatheter closure of oval shaped atrial septal defect with amplatzer septal occluder.

Authors:  Jinyoung Song; Sang Yoon Lee; Jae Sook Baek; Woo Seub Shim; Eun Young Choi
Journal:  Yonsei Med J       Date:  2013-09       Impact factor: 2.759

View more