Literature DB >> 19933190

A theoretical model for predicting interfacial relationships of retinal tamponades.

Ian Eames1, Romesh I Angunawela, G William Aylward, Ali Azarbadegan.   

Abstract

Purpose. To establish a theoretical model to determine the relationship between retinal coverage and tamponade shape in relation to tamponade volume, for a variety of tamponades, and to test these relationships with a physical analogue of the human eye. Methods. The theoretical model was based on a static balance between buoyancy forces and surface tension forces, for an axisymmetrically shaped bubble or droplet. In the laboratory experiments, two hemispheres were cut into an acrylic block. The acrylic was soaked with bovine serum for 10 minutes to ensure that the wetting properties were similar to the human retina. Photographic images of various fractions of lighter-than-water (gas, silicone) and heavier-than-water (Oxane HD) tamponades were analyzed by using algorithms written in commercial image-processing software and compared with the theoretical predictions and published data. Results. The theoretical predictions of tamponade shape and retinal coverage agree closely with the results obtained from the analogue experiments. Conclusions. The theoretical model was validated against measurements in a human eye analogue and published data. The three key parameters that characterize the retinal coverage of any given tamponade are the bond number, the contact angle of the tamponade, and the volume used. The model may be used to predict the static properties of new tamponades without in vivo tests.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19933190     DOI: 10.1167/iovs.09-4442

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  7 in total

1.  Influence of sutureless 23-gauge sclerotomy architecture on postoperative intraocular pressure decrease: results of a multivariate analysis.

Authors:  Rachid Tahiri Joutei Hassani; Mohamed El Sanharawi; Raphael Adam; Claire Monin; Sylvère Dupont-Monod; Christophe Baudouin
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-30       Impact factor: 3.117

2.  Silicone Oil Tamponade-Retina Contact in Highly Myopic Eyes With and Without Encircling Bands: A Computational Fluid Dynamics Study.

Authors:  Tommaso Rossi; Giorgio Querzoli; Maria Grazia Badas; Federico Angius; Guido Ripandelli
Journal:  Transl Vis Sci Technol       Date:  2022-06-01       Impact factor: 3.048

3.  Gas-Graft Coverage After DMEK: A Clinically Validated Numeric Study.

Authors:  Jan O Pralits; Mark Alberti; Javier Cabreizo
Journal:  Transl Vis Sci Technol       Date:  2019-11-12       Impact factor: 3.283

Review 4.  Biocompatibility of intraocular liquid tamponade agents: an update.

Authors:  Mario R Romano; Mariantonia Ferrara; Irene Nepita; Jana D'Amato Tothova; Alberto Giacometti Schieroni; Daniela Reami; Raniero Mendichi; Libero Liggieri; Rodolfo Repetto
Journal:  Eye (Lond)       Date:  2021-05-25       Impact factor: 4.456

5.  Mechanical models of the dynamics of vitreous substitutes.

Authors:  Krystyna Isakova; Jan O Pralits; Rodolfo Repetto; Mario R Romano
Journal:  Biomed Res Int       Date:  2014-07-24       Impact factor: 3.411

6.  Assessment of Postural Compliance After Pneumatic Retinopexy.

Authors:  Raul Velez-Montoya; Ana González-H León; Everardo Hernández-Quintela
Journal:  Transl Vis Sci Technol       Date:  2019-05-02       Impact factor: 3.283

7.  Objective analysis of perfluoropropane tamponade area after pars plana vitrectomy using ultra-widefield fundus stereographic projection images.

Authors:  Mihyun Choi; Suji Hong; Cheolmin Yun; Seong-Woo Kim
Journal:  Sci Rep       Date:  2020-10-26       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.