Literature DB >> 19931011

Rotation of the sacrum during bellyboard pelvic radiotherapy.

Mladen Kasabasić1, Dario Faj, Ana Ivković, Slaven Jurković, Nenad Belaj.   

Abstract

Patients with cervical, uterine, and rectal carcinomas are usually treated in the prone position using the bellyboard positioning device. Specific and uncomfortable prone position gives rise to uncertainties in the daily set-up of patients during the treatment. During investigation of translational movements, rotational movements of the pelvis are observed and investigated. The film portal imaging is used to discover patient positioning errors during treatment. We defined the rotational set-up errors by angle deviations of the sacrum. Thirty-six patients were included in the study; 15 patients were followed during the whole treatment and 21 during the first 5 consecutive treatment days. The image acquisitions were completed in 84%. Systematic and random positioning errors were analyzed in 725 images. Approximately half of the patients had adjusted to the bellyboard in the first few fractions, with sacrum angles remaining the same for the rest of the treatment. The other half had drifts of the sacrum angle during the whole treatment. The rotation of the sacrum during treatment ranged up to 14 degrees , causing the usual set-up verification and correction procedure to result in errors up to 15 mm. Rotational movements of the patient pelvis during bellyboard pelvis radiotherapy can introduce considerable patient position error. Copyright 2010 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19931011     DOI: 10.1016/j.meddos.2009.01.001

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  3 in total

1.  In vivo Portal Imaging Dosimetry Identifies Delivery Errors in Rectal Cancer Radiotherapy on the Belly Board Device.

Authors:  Stefano Peca; Richie Siddhartha Sinha; Derek Wilson Brown; Wendy Lani Smith
Journal:  Technol Cancer Res Treat       Date:  2017-06-06

2.  How much margin do we need for pelvic lymph nodes irradiation in the era of IGRT?

Authors:  Zhikai Liu; Xia Liu; Fuquan Zhang; Ke Hu
Journal:  J Cancer       Date:  2018-09-08       Impact factor: 4.207

3.  Robustness of elective lymph node target coverage with shrinking Planning Target Volume margins in external beam radiotherapy of locally advanced cervical cancer.

Authors:  Thomas Berger; Lars U Fokdal; Marianne S Assenholt; Nina B K Jensen; Jørgen B B Petersen; Lars Nyvang; Stine Korreman; Jacob C Lindegaard; Kari Tanderup
Journal:  Phys Imaging Radiat Oncol       Date:  2019-06-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.