BACKGROUND: Poor adherence to antihypertensive medication is one of the major problems in the treatment of hypertension. Electronic monitoring is currently considered to be the gold standard for assessing adherence, but it may trigger patients to open the pill bottle without taking medication or to take out more than prescribed. In adjunct to electronic monitoring, pill count could be a valuable tool for exploring adherence patterns, and their effects on blood pressure reduction. METHODS: Among a total of 228 patients with mild-to-moderate hypertension, adherence to treatment was measured by means of both the Medication Event Monitoring System (MEMS) and pill count. Patients were followed-up for seven visits over a period of 1 year. At each visit to the physician's office, patient's adherence was assessed by both methods. RESULTS: Adherence is defined as the percentage of days with correct dosing; median adherence according to MEMS was lower than median adherence according to pill count (91.6 vs. 96.1; P < 0.001). Both methods agreed in defining patients as adherent in 107 (47%) and nonadherent in 33 (14%) patients. Thirty-one (14%) patients were adherent only by MEMS and 59 (25%) patients only by pill count. At the end of the study, patients in the four categories reached comparable blood pressure values and reductions. CONCLUSIONS: Pill count could be a useful adjunct to electronic monitoring in assessing adherence patterns. Although deviant intake behavior occurred frequently, the effect on achieved blood pressure and blood pressure reduction was not remarkable.
RCT Entities:
BACKGROUND: Poor adherence to antihypertensive medication is one of the major problems in the treatment of hypertension. Electronic monitoring is currently considered to be the gold standard for assessing adherence, but it may trigger patients to open the pill bottle without taking medication or to take out more than prescribed. In adjunct to electronic monitoring, pill count could be a valuable tool for exploring adherence patterns, and their effects on blood pressure reduction. METHODS: Among a total of 228 patients with mild-to-moderate hypertension, adherence to treatment was measured by means of both the Medication Event Monitoring System (MEMS) and pill count. Patients were followed-up for seven visits over a period of 1 year. At each visit to the physician's office, patient's adherence was assessed by both methods. RESULTS: Adherence is defined as the percentage of days with correct dosing; median adherence according to MEMS was lower than median adherence according to pill count (91.6 vs. 96.1; P < 0.001). Both methods agreed in defining patients as adherent in 107 (47%) and nonadherent in 33 (14%) patients. Thirty-one (14%) patients were adherent only by MEMS and 59 (25%) patients only by pill count. At the end of the study, patients in the four categories reached comparable blood pressure values and reductions. CONCLUSIONS: Pill count could be a useful adjunct to electronic monitoring in assessing adherence patterns. Although deviant intake behavior occurred frequently, the effect on achieved blood pressure and blood pressure reduction was not remarkable.
Authors: Taneisha S Buchanan; Carla J Berg; Lisa Sanderson Cox; Niaman Nazir; Neal L Benowitz; Lisa Yu; Olivia Yturralde; Peyton Jacob; Won S Choi; Jasjit S Ahluwalia; Nicole L Nollen Journal: Nicotine Tob Res Date: 2012-02-24 Impact factor: 4.244
Authors: Shivan J Mehta; Kevin G Volpp; Andrea B Troxel; Susan C Day; Raymond Lim; Noora Marcus; Laurie Norton; Sophia Anderson; David A Asch Journal: J Gen Intern Med Date: 2019-08-08 Impact factor: 5.128
Authors: Rachel O'Conor; Marina Arvanitis; Guisselle Wismer; Lauren Opsasnick; Angela Sanchez Muñoz; Joseph Kannry; Jenny J Lin; Darren Kaiser; Mary J Kwasny; Stephen D Persell; Ruth Parker; Alastair J J Wood; Alex D Federman; Michael S Wolf Journal: Contemp Clin Trials Date: 2019-06-28 Impact factor: 2.226
Authors: J L Marcus; T Buisker; T Horvath; K R Amico; J D Fuchs; S P Buchbinder; R M Grant; A Y Liu Journal: HIV Med Date: 2014-02-24 Impact factor: 3.180