Literature DB >> 19927099

C1 lateral mass-C2 pedicle screws and crosslink compression fixation for unstable atlas fracture.

Jun Tan1, Lijun Li, Guixin Sun, Lie Qian, Mingjie Yang, Cheng Zeng, Honglin Teng, Lianshun Jia.   

Abstract

STUDY
DESIGN: Primary clinical trial of limited fixation for unstable Atlas fracture.
OBJECTIVES: To clinically validate feasibility, safety and value of the C1 later-mass screw C2 pedicle screw and crosslink compression fixation technique. SUMMARY OF BACKGROUND DATA: [corrected] In previous clinical studies, several techniques have been introduced to fix Atlas fracture. But all these treatments have intrinsic disadvantages. Now seeking a means of limited internal fixation has become a worthwhile subject of clinical study.
MATERIALS AND METHODS: From January 2001 to December 2004, 17 cases of atlas fracture were diagnosed consecutively, 11 cases were operated on with C1 lateral mass and C2 pedicle screws and crosslink fixation, of whom 6 patents had axial instability and rupture of transverse ligament, 1 patient had C2 laminal fracture, and the remaining 4 patients had axial instability. With the assistant of regional anatomy study and fluoroscopy C1 lateral mass screws and C2 pedicle screws were implanted in place, between which connecting rods were applied bilaterally. A crosslink compression was applied between the 2 rods to achieve realignment of C1 lateral mass fracture and C0-C1-C2 into the anatomic position. C1-C2 fusion with posterior bone grafting was performed in patients with axial instability or transverse ligament discontinuity.
RESULTS: Operative time ranged from 90 to 176 minutes with a mean of 124 minutes. Intraoperative blood loss ranged from 270 to 1200 mL with a mean of 432 mL. There were no neurologic deficits, vertebral artery related complications or other complications in all patients. No deterioration of the neurologic deficits was noticed 5 days after operation when the patients were brace fixed and began to ambulate. No cerebral hemodynamic deficit was observed in this patient. Radiograph examination showed bone fusion and stability in all patients 3 months after operation. Healing of C2 fracture was confirmed by computed tomography scan.
CONCLUSION: Osteosynthesis of the atlas by C1 lateral mass screws C2 pedicle screws and crosslink compression fixation is an ideal option for C1 burst fracture with or without rupture of the transverse ligament. The procedure allows for partially physiologic reconstruction of the C0-C1-C2 joint and shortens external fixation.

Entities:  

Mesh:

Year:  2009        PMID: 19927099     DOI: 10.1097/BRS.0b013e3181b4009a

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  7 in total

1.  The height for screw index (HSI) predicts the development of C2 nerve dysfunction associated with C1 lateral mass screw fixation for atlantoaxial instability.

Authors:  Da-Geng Huang; Ding-Jun Hao; Yong-Hong Jiang; Yue Cheng; Jun-Wei Pan; Yong-Qian Qiang; Bao-Rong He; Li-Xiong Qian
Journal:  Eur Spine J       Date:  2014-02-26       Impact factor: 3.134

2.  Occipital neuralgia after occipital cervical fusion to treat an unstable jefferson fracture.

Authors:  Seong Ju Kong; Jin Hoon Park; Sung Woo Roh
Journal:  Korean J Spine       Date:  2012-12-31

3.  Comparison of occipitocervical and atlantoaxial fusion in treatment of unstable Jefferson fractures.

Authors:  Yong Hu; Zhen-Shan Yuan; Christopher K Kepler; Wei-Xin Dong; Xiao-Yang Sun; Jiao Zhang
Journal:  Indian J Orthop       Date:  2017 Jan-Feb       Impact factor: 1.251

4.  Posterior arthrodesis of C1-C3 for the stabilization of multiple unstable upper cervical fractures with spinal cord compromise: A case report and literature review.

Authors:  Deting Xue; Qixin Chen; Gang Chen; Wenhai Zhuo; Fangcai Li
Journal:  Medicine (Baltimore)       Date:  2017-01       Impact factor: 1.889

5.  Direct Internal Fixation for Unstable Atlas Fractures.

Authors:  Jae-Won Shin; Kyung-Soo Suk; Hak-Sun Kim; Jae-Ho Yang; Ji-Won Kwon; Hwan-Mo Lee; Sung-Hwan Moon; Byung-Ho Lee; Sang-Jun Park; Sub-Ri Park; Sun-Kyu Kim
Journal:  Yonsei Med J       Date:  2022-03       Impact factor: 2.759

Review 6.  Improving C1-C2 Complex Fusion Rates: An Alternate Approach.

Authors:  Samer S Ghostine; Paul E Kaloostian; Christ Ordookhanian; Sean Kaloostian; Parham Zarrini; Terrence Kim; Stephen Scibelli; Scott J Clark-Schoeb; Srinath Samudrala; Carl Lauryssen; Amandip S Gill; Patrick J Johnson
Journal:  Cureus       Date:  2017-11-29

7.  Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis.

Authors:  Parisa Azimi; Taravat Yazdanian; Edward C Benzel; Hossein Nayeb Aghaei; Shirzad Azhari; Sohrab Sadeghi; Ali Montazeri
Journal:  J Orthop Surg Res       Date:  2020-07-20       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.