The geometric calibration of cone-beam systems with arbitrary geometry.

Normand Robert1, Kristina N Watt, Xinying Wang, James G Mainprize.   

Abstract

A method is proposed to determine the cone-beam x-ray acquisition geometry of an imaging system using a phantom consisting of discrete x-ray opaque markers defining two parallel rings sharing a common axis. The phantom generates an image of two ellipses which are fitted to an ellipse model. A phantom-centric coordinate system is used to simplify the equations describing the ellipse coefficients such that a solution describing the acquisition geometry can be obtained via numerical optimization of only three of the nine unknown variables. We perform simulations to show how errors in the fit of the ellipse coefficients affect estimates of the acquisition geometries. These simulations show that for ellipse projections sampled with 1200 markers, 25 microm errors in marker positions and a source-detector distance (SDD) of 1.6 m, we can measure angles describing detector rotation with a mean error of <0.002 degrees and a standard deviation (SD) of <0.03 degrees. The SDD has a mean error of 0.004 mm and SD = 0.24 mm. The largest error is associated with the determination of the point on the detector closest to the x-ray source (mean error = 0.05 mm, SD = 0.85 mm). A prototype phantom was built and results from x-ray experiments are presented.

Entities:  

Mesh:

Year:  2009        PMID: 19926916     DOI: 10.1088/0031-9155/54/24/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Estimation of CT cone-beam geometry using a novel method insensitive to phantom fabrication inaccuracy: implications for isocenter localization accuracy.

Authors:  J Chetley Ford; Dandan Zheng; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

2.  Set-up error validation with EPID images: Measurements vs Egs_cbct simulation.

Authors:  D van Eeden; F H J O'Reilly; F C P du Plessis
Journal:  Rep Pract Oncol Radiother       Date:  2019-10-21

3.  Geometric calibration of a stationary digital breast tomosynthesis system based on distributed carbon nanotube X-ray source arrays.

Authors:  Changhui Jiang; Na Zhang; Juan Gao; Zhanli Hu
Journal:  PLoS One       Date:  2017-11-29       Impact factor: 3.240

4.  A simulation-based method for evaluating geometric tests of a linac c-arm in quality control in radiotherapy.

Authors:  Mateusz Baran; Krzysztof Rzecki; Damian Kabat; Monika Tulik; Anna Wydra; Zuzanna Derda; Agata Sochaczewska; Zbisław Tabor
Journal:  J Appl Clin Med Phys       Date:  2019-09-14       Impact factor: 2.102