Literature DB >> 19925915

Ionic liquid-based dispersive liquid-liquid microextraction followed high-performance liquid chromatography for the determination of organophosphorus pesticides in water sample.

Lijun He1, Xianli Luo, Hongxue Xie, Chunjian Wang, Xiuming Jiang, Kui Lu.   

Abstract

Using 1-octyl-3-methylimidazolium hexafluorophosphate ([C(8)MIM][PF(6)]) ionic liquid as extraction solvent, organophosphorus pesticides (OPPs) (parathion, phoxim, phorate and chlorpyifos) in water were determined by dispersive liquid-liquid microextraction (DLLME) combined with high-performance liquid chromatography (HPLC). The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of [C(8)MIM][PF(6)] dispersed entirely into sample solution with the help of disperser solvent (methanol). Parameters including extraction solvent and its volume, disperser solvent and its volume, extraction time, centrifugal time, salt addition, extraction temperature and sample pH were investigated and optimized. Under the optimized conditions, up to 200-fold enrichment factor of analytes and acceptable extraction recovery (>70%) were obtained. The calibration curves were linear in the concentration range of 10.5-1045.0 microg L(-1) for parathion, 10.2-1020.0 microg L(-1) for phoxim, 54.5-1089.0 microg L(-1) for phorate and 27.2-1089.0 microg L(-1) for chlorpyifos, respectively. The limits of detection calculated at a signal-to-noise ratio of 3 were in the range of 0.1-5.0 microg L(-1). The relative standard deviations for seven replicate experiments at 200 microg L(-1) concentration level were less than 4.7%. The proposed method was applied to the analysis of four different sources water samples (tap, well, rain and Yellow River water) and the relative recoveries of spiked water samples are 99.9-115.4%, 101.8-113.7% and 87.3-117.6% at three different concentration levels of 75, 200 and 1000 microg L(-1), respectively.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19925915     DOI: 10.1016/j.aca.2009.09.044

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

1.  Electrochemical aptasensor based on Mo2C/Mo2N and gold nanoparticles for determination of chlorpyrifos.

Authors:  Zhenfeng Lin; Xin Liu; Yangzi Li; Changxiang Li; Liu Yang; Keke Ma; Zhenwei Zhang; Huayu Huang
Journal:  Mikrochim Acta       Date:  2021-04-23       Impact factor: 5.833

Review 2.  Green aspects of techniques for the determination of currently used pesticides in environmental samples.

Authors:  Jolanta Stocka; Maciej Tankiewicz; Marek Biziuk; Jacek Namieśnik
Journal:  Int J Mol Sci       Date:  2011-11-10       Impact factor: 5.923

Review 3.  Recent applications of ionic liquids in separation technology.

Authors:  Dandan Han; Kyung Ho Row
Journal:  Molecules       Date:  2010-04-05       Impact factor: 4.411

4.  Detecting and Mapping Harmful Chemicals in Fruit and Vegetables Using Nanoparticle-Enhanced Laser-Induced Breakdown Spectroscopy.

Authors:  Xiande Zhao; Chunjiang Zhao; Xiaofan Du; Daming Dong
Journal:  Sci Rep       Date:  2019-01-29       Impact factor: 4.379

5.  Development of a Efficient and Sensitive Dispersive Liquid-Liquid Microextraction Technique for Extraction and Preconcentration of 10 β2-Agonists in Animal Urine.

Authors:  Yang Li; Wei Zhang; Rui-Guo Wang; Pei-Long Wang; Xiao-Ou Su
Journal:  PLoS One       Date:  2015-09-08       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.