Literature DB >> 19925342

Fitting range of the BAHA Intenso.

Arjan J Bosman1, F M Snik, Emmanuel A M Mylanus, W R J Cremers.   

Abstract

Audiometric characteristics of a recently introduced more powerful, behind-the-ear, BAHA sound processor, the BAHA Intenso, were evaluated in 23 patients with contra-indications for using conventional hearing aids. All patients had mixed hearing loss with boneconduction thresholds ranging between 30 and 50 dB HL. Boneconduction gain, defined as the difference in aided free-field detection thresholds and unaided boneconduction thresholds, was calculated at the octave frequencies between 500 Hz and 4 kHz. Median boneconduction gain of the Intenso ranges from 0 dB at 500 ;Hz to 12 ;dB at 2 kHz with substantial interindividual variability. The upper limit of the BAHA Intenso's fitting range was established by requiring aided speech reception thresholds with CVC-monosyllables of at most 60 dB SPL. The fitting range of the BAHA Intenso appeared to be limited to 42, 44, 58, and 48 dB HL for boneconduction thresholds at 0.5, 1, 2, and 4 ;kHz, respectively. Loudness growth functions at 0.5 and 3 kHz as obtained with 7-point categorical scaling showed an adequate aided dynamic range.

Entities:  

Mesh:

Year:  2009        PMID: 19925342     DOI: 10.1080/14992020802662956

Source DB:  PubMed          Journal:  Int J Audiol        ISSN: 1499-2027            Impact factor:   2.117


  4 in total

1.  Influence of directionality and maximal power output on speech understanding with bone anchored hearing implants in single sided deafness.

Authors:  Silvia Krempaska; Juraj Koval; Christoph Schmid; Flurin Pfiffner; Anja Kurz; Martin Kompis
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-05-23       Impact factor: 2.503

Review 2.  [Differential indication of active middle ear implants].

Authors:  K Braun; H-P Zenner; N Friese; A Tropitzsch
Journal:  HNO       Date:  2015-06       Impact factor: 1.284

3.  Influence of implantable hearing aids and neuroprosthesison music perception.

Authors:  Torsten Rahne; Lars Böhme; Gerrit Götze
Journal:  ScientificWorldJournal       Date:  2012-05-03

4.  Hearing performance benefits of a programmable power baha® sound processor with a directional microphone for patients with a mixed hearing loss.

Authors:  Mark C Flynn; Annelen Hedin; Glenn Halvarsson; Tobias Good; Andre Sadeghi
Journal:  Clin Exp Otorhinolaryngol       Date:  2012-04-30       Impact factor: 3.372

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.