Literature DB >> 19924001

Rationale and design of the Randomized comparison of XiEnce V and Multilink VisioN coronary stents in the sAme muLtivessel patient with chronic kiDnEy disease (RENAL-DES) study.

Fabrizio Tomai1, Alessandro Petrolini, Leonardo De Luca, Francesco Nudi, Gaetano Lanza, Corrado Vassanelli, Flavio Ribichini.   

Abstract

BACKGROUND: Percutaneous coronary intervention with bare metal stents (BMS) in patients with chronic kidney disease (CKD) has shown suboptimal results. Drug-eluting stents (DESs) might reduce the incidence of restenosis and therefore of target lesion revascularization in these patients. Of note, in patients with CKD, multiple concomitant individual variables may be responsible for neointimal hyperplasia after coronary stenting, thus making the comparison of BMS and DES in different patient groups difficult. STUDY
DESIGN: The RENAL-DES is a prospective, randomized, multicenter, not-sponsored study to directly compare the efficacy in the prevention of clinical restenosis, of everolimus-eluting stent (Xience V) and BMS with identical design (Multilink Vision), both implanted in the same patient with multivessel coronary artery disease and CKD in order to obviate the multiple and unpredictable baseline differences. The primary endpoint of the study is 9-month ischemia-driven target vessel revascularization. SAMPLE SIZE: The expected primary endpoint rates are 20% for BMS and 10% for DES. According to these estimates, with a significant level of 0.05, a sample size of 194 patients provides an 80% statistical power. Assuming a 10% dropout rate, the goal is to enroll 213 patients (426 treated vessels) from five Italian centers. As 20% of the patients will likely require stent implantation in three vessels, approximately 500 treated vessels will be analyzed.
CONCLUSION: This intraindividual, randomized study will provide, for the first time, data on the efficacy, in the prevention of clinical restenosis, of DES compared to BMS in patients with multivessel coronary artery disease and CKD (ClinicalTrials.gov Identifier: NCT 00818792).

Entities:  

Mesh:

Year:  2010        PMID: 19924001     DOI: 10.2459/JCM.0b013e3283347e24

Source DB:  PubMed          Journal:  J Cardiovasc Med (Hagerstown)        ISSN: 1558-2027            Impact factor:   2.160


  2 in total

1.  Drug-eluting stent or coronary artery bypass graft surgery in hemodialysis patients?

Authors:  Flavio Ribichini; Corrado Vassanelli
Journal:  J Nephrol       Date:  2013-12-13       Impact factor: 3.902

Review 2.  Comparison of Drug-Eluting and Bare Metal Stents in Patients With Chronic Kidney Disease: An Updated Systematic Review and Meta-Analysis.

Authors:  Renjie Lu; Fenglei Tang; Yan Zhang; Xishan Zhu; Shanmei Zhu; Ganlin Wang; Yinfeng Jiang; Zhengda Fan
Journal:  J Am Heart Assoc       Date:  2016-11-07       Impact factor: 5.501

  2 in total