James C Worrall1. 1. Department of Emergency Medicine, University of Ottawa, Ottawa, Ontario, Canada. jworrall@rogers.com
Abstract
OBJECTIVE: The primary objective of this study was to compare the results of nurse-performed urinalysis (NPU) interpreted visually in the emergency department (ED) with laboratory performed urinalysis (LPU) interpreted by reflectance photometry. METHODS: This was a prospective observational study based on a convenience sample from my emergency practice. Emergency nurses, who were unaware of the study, performed usual dipstick analysis before sending the same urine sample to the laboratory for testing. RESULTS: Of 140 urinalyses performed during the study period, 124 were suitable for analysis. When compared with the reference standard LPU, the NPU had an overall sensitivity of 100% (95% confidence interval [CI] 95%-100%) and a specificity of 49% (95% CI 33%-65%) for the presence of any 1 of blood, leukocyte esterase, nitrites, protein, glucose or ketones in the urine. Of 20 falsely positive NPUs, 18 were a result of the nurse recording 1 or more components as "trace" positive. CONCLUSION: Although NPU does not yield identical results to LPU, a negative LPU is expected when the initial NPU in the ED is negative.
OBJECTIVE: The primary objective of this study was to compare the results of nurse-performed urinalysis (NPU) interpreted visually in the emergency department (ED) with laboratory performed urinalysis (LPU) interpreted by reflectance photometry. METHODS: This was a prospective observational study based on a convenience sample from my emergency practice. Emergency nurses, who were unaware of the study, performed usual dipstick analysis before sending the same urine sample to the laboratory for testing. RESULTS: Of 140 urinalyses performed during the study period, 124 were suitable for analysis. When compared with the reference standard LPU, the NPU had an overall sensitivity of 100% (95% confidence interval [CI] 95%-100%) and a specificity of 49% (95% CI 33%-65%) for the presence of any 1 of blood, leukocyte esterase, nitrites, protein, glucose or ketones in the urine. Of 20 falsely positive NPUs, 18 were a result of the nurse recording 1 or more components as "trace" positive. CONCLUSION: Although NPU does not yield identical results to LPU, a negative LPU is expected when the initial NPU in the ED is negative.
Authors: Carlan Bruce Wendler; Ladislas Mashimango; Temoi Remi; Patrick LaRochelle; Elliot Kang; B Jason Brotherton Journal: Afr J Emerg Med Date: 2022-05-13
Authors: Louise Watson; Amanda R W Richardson; Richard C L Holt; Caroline A Jones; Michael W Beresford Journal: PLoS One Date: 2012-01-03 Impact factor: 3.240