Literature DB >> 19922310

Dobutamine stress cardiovascular magnetic resonance imaging in patients after invasive coronary revascularization with stent placement.

C Heilmaier1, O Bruder, F Meier, M Jochims, M Forsting, G V Sabin, J Barkhausen, T W Schlosser.   

Abstract

BACKGROUND: High-dose dobutamine stress magnetic resonance (DSMR) is a well-established imaging technique for the detection of coronary artery disease (CAD).
PURPOSE: To investigate the value of DSMR for the detection of in-stent restenoses (ISR) in patients with prior coronary stenting, using invasive coronary angiography (ICA) as the standard of reference.
MATERIAL AND METHODS: 50 patients with 74 stents and without wall motion abnormalities at rest were examined on a 1.5T MR scanner and underwent ICA for clinical reasons within 14 days after DSMR examination. A dobutamine/atropine stress protocol was employed until age-predicted heart rate was achieved, and imaging was performed in at least three long- and three short-axis views using a segmented steady-state free precession sequence (repetition/echo time [TR/TE] 3/1.5 ms, flip angle 60 degrees). All examinations were read by an experienced cardiologist and radiologist in consensus, with myocardial ischemia being defined as a new stress-induced wall motion abnormality in at least one myocardial segment. Statistical analysis was performed on a per-vessel (left circumflex artery [LCX], left anterior descending artery [LAD], and right coronary artery [RCA]) basis and with regard to the number of affected vessels (one-, two- or three-vessel disease).
RESULTS: ICA yielded seven ISR, of which one was missed by DSMR (sensitivity 86%, 95% confidence interval [CI] 0.42-0.99). Sixty-seven coronary arteries showed no ISR in ICA; however, due to new wall motion abnormalities, seven ISR were suspected in DSMR (2xRCA, 3xLCX, and 2xLAD; sensitivity 86%, specificity 90%, positive predictive value 46%, negative predictive value 98%, and diagnostic accuracy 89%). The per-vessel analysis of the three main coronary arteries revealed highest sensitivity (100%), specificity (93%), and diagnostic accuracy (94%) for the LAD.
CONCLUSION: High-dose DSMR is an accurate, noninvasive technique for the detection of ISR and reliably allows identification of patients who need to undergo control ICA.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19922310     DOI: 10.3109/02841850903216692

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  2 in total

Review 1.  Pharmacological stress cardiovascular magnetic resonance.

Authors:  Runyawan Chotenimitkhun; W Gregory Hundley
Journal:  Postgrad Med       Date:  2011-05       Impact factor: 3.840

Review 2.  Role of cardiac magnetic resonance in the evaluation of dilated cardiomyopathy: diagnostic contribution and prognostic significance.

Authors:  Marco Francone
Journal:  ISRN Radiol       Date:  2014-02-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.