Literature DB >> 19921510

Determination of 19 drugs of abuse and metabolites in whole blood by high-performance liquid chromatography-tandem mass spectrometry.

Marie Kjaergaard Bjørk1, Marie K K Nielsen, Lotte Ø Markussen, Helene B Klinke, Kristian Linnet.   

Abstract

A high-performance liquid chromatography (LC)-tandem mass spectrometry (MS/MS) method has been developed and validated for the determination of 19 drugs of abuse and metabolites and used in whole blood. The following compounds were included: amphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylenedioxymethamphetamine, methamphetamine, cocaine, benzoylecgonine, morphine, 6-acetylmorphine, codeine, methadone, buprenorphine, norbuprenorphine, ketobemidone, tramadol, O-desmethyltramadol, zaleplone, zolpidem, and zopiclone. The sample pretreatment consisted of solid-phase extraction using mixed-mode columns (Isolute Confirm HCX). Deuterated analogues were used as internal standards for all analytes, except for ketobemidone and O-desmethyltramadol. The analytes were separated by a methanol/ammonium formate gradient using high-performance LC (Agilent HPLC 1100) with a 3 mm x 100 mm Varian Pursuit 3 C(18) column, 3-microm particle size, and were quantified by MS/MS (Waters Quattro micro tandem quadrupole mass spectrometer) using multiple reaction monitoring in positive mode. Two transitions were used for all analytes, except for tramadol and O-desmethyltramadol. The run time of the method was 35 min including the equilibration time. For all analytes, responses were linear over the range investigated, with R(2) > 0.99. One-point calibration was found to be adequate by validation, thereby saving analysis of multiple calibrators. The limits of quantification (LOQs) for the analytes ranged from 0.0005 to 0.01 mg/kg. Absolute recoveries of the analytes were from 34 to 97%, except for zaleplone (6%). Both the interday precision and the intraday precision were less than 15% (20% at the LOQ) for all analytes, except buprenorphine, norburprenorphine, and zaleplone (less than 18%). Accuracy (bias) was within +/-15% (+/-20% at the LOQ) for all analytes, except MDMA and O-desmethyltramadol (within +/-19%). No ion suppression or enhancement was seen nor was suppression from coeluted analytes seen. Matrix effects were found to be less than 23% for all analytes, except zopiclone (64%). High-concentration and low-concentration quality control samples gave acceptable values, and the method has been tried in international proficiency test schemes with good results. The present LC-MS/MS method provides a simple, specific, and sensitive solution for the quantification of some of the most frequent drugs of abuse and their metabolites in whole blood. The quantification by LC-MS/MS was successfully applied to 412 forensic cases from October 2008 to mid February 2009, where 267 cases were related to zero-tolerance traffic legislation.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19921510     DOI: 10.1007/s00216-009-3268-9

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  6 in total

1.  Novel Selectivity-Based Forensic Toxicological Validation of a Paper Spray Mass Spectrometry Method for the Quantitative Determination of Eight Amphetamines in Whole Blood.

Authors:  Sebastiaan F Teunissen; Patrick W Fedick; Bjorn J A Berendsen; Michel W F Nielen; Marcos N Eberlin; R Graham Cooks; Arian C van Asten
Journal:  J Am Soc Mass Spectrom       Date:  2017-09-06       Impact factor: 3.109

Review 2.  A review of the modern principles and applications of solid-phase extraction techniques in chromatographic analysis.

Authors:  Mohamed E I Badawy; Mahmoud A M El-Nouby; Paul K Kimani; Lee W Lim; Entsar I Rabea
Journal:  Anal Sci       Date:  2022-10-05       Impact factor: 1.967

3.  3,4-Methylenedioxymethamphetamine (MDMA) and metabolites disposition in blood and plasma following controlled oral administration.

Authors:  Rebecca L Hartman; Nathalie A Desrosiers; Allan J Barnes; Keming Yun; Karl B Scheidweiler; Erin A Kolbrich-Spargo; David A Gorelick; Robert S Goodwin; Marilyn A Huestis
Journal:  Anal Bioanal Chem       Date:  2013-11-15       Impact factor: 4.142

4.  Simultaneous quantitation of folates, flavins and B6 metabolites in human plasma by LC-MS/MS assay: Applications in colorectal cancer.

Authors:  Isaac Asante; Hua Pei; Eugene Zhou; Siyu Liu; Darryl Chui; EunJeong Yoo; Stan G Louie
Journal:  J Pharm Biomed Anal       Date:  2018-05-22       Impact factor: 3.935

5.  Comprehensive automation of the solid phase extraction gas chromatographic mass spectrometric analysis (SPE-GC/MS) of opioids, cocaine, and metabolites from serum and other matrices.

Authors:  Oliver Lerch; Oliver Temme; Thomas Daldrup
Journal:  Anal Bioanal Chem       Date:  2014-05-02       Impact factor: 4.142

6.  Seizures of illicit substances for personal use in two Italian provinces: analysis of trends by type and purity from 2008 to 2017.

Authors:  Patrizia Verri; Cecilia Rustichelli; Anna Ferrari; Filippo Marchesi; Carlo Baraldi; Manuela Licata; Daniele Vandelli; Federica Palazzoli; Francesco Potì; Enrico Silingardi
Journal:  Subst Abuse Treat Prev Policy       Date:  2019-09-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.