INTRODUCTION: We evaluated the coronary balloon-expandable cobalt chromium stent Coroflex Blue for the treatment of intracranial atherosclerotic arterial stenoses (IAAS). METHODS: Between March 2007 and October 2007, a total of 25 patients (20 male, age median 67 years) with 30 IAAS underwent endovascular treatment using Coroflex Blue stents (B. Braun, Germany). Location and degree of target stenoses before and after treatment and at follow-up and adverse clinical sequelae of treatment were registered. Angiographic follow-up was scheduled for 6, 12, 26, and 52 weeks after the treatment. RESULTS: The 30 treated lesions were located as follows: nine in intracranial-extradural internal carotid artery (ICA), three in intradural ICA, five in middle cerebral artery, eight in intradural vertebral artery, and five in basilar artery. The technical success rate was 100%. The degree of stenoses prior to and after treatment was 61 +/- 2% and 26 +/- 3% (mean +/- SE), respectively. A residual stenosis of <50% was achieved in 29 (97%) procedures. Treatment was uneventful in 28 out of 30 procedures (93%); one patient suffered a transient and one patient a permanent neurological deficit. Angiographic follow-up was available in all of the patients (100%) after 15.2 months (median) and showed significant (i.e., more than 50%) degree of recurrent stenosis in 11 (37%) of the lesions. Retreatment was performed in 11 (37%) lesions. CONCLUSION: The Coroflex Blue stent is easily inserted and safely deployed into intracranial arteries. The incidence of recurrent stenoses remains a concern. Stringent angiographic and clinical follow-up and retreatment are therefore mandatory.
INTRODUCTION: We evaluated the coronary balloon-expandable cobalt chromium stentCoroflex Blue for the treatment of intracranial atherosclerotic arterial stenoses (IAAS). METHODS: Between March 2007 and October 2007, a total of 25 patients (20 male, age median 67 years) with 30 IAAS underwent endovascular treatment using Coroflex Blue stents (B. Braun, Germany). Location and degree of target stenoses before and after treatment and at follow-up and adverse clinical sequelae of treatment were registered. Angiographic follow-up was scheduled for 6, 12, 26, and 52 weeks after the treatment. RESULTS: The 30 treated lesions were located as follows: nine in intracranial-extradural internal carotid artery (ICA), three in intradural ICA, five in middle cerebral artery, eight in intradural vertebral artery, and five in basilar artery. The technical success rate was 100%. The degree of stenoses prior to and after treatment was 61 +/- 2% and 26 +/- 3% (mean +/- SE), respectively. A residual stenosis of <50% was achieved in 29 (97%) procedures. Treatment was uneventful in 28 out of 30 procedures (93%); one patient suffered a transient and one patient a permanent neurological deficit. Angiographic follow-up was available in all of the patients (100%) after 15.2 months (median) and showed significant (i.e., more than 50%) degree of recurrent stenosis in 11 (37%) of the lesions. Retreatment was performed in 11 (37%) lesions. CONCLUSION: The Coroflex Blue stent is easily inserted and safely deployed into intracranial arteries. The incidence of recurrent stenoses remains a concern. Stringent angiographic and clinical follow-up and retreatment are therefore mandatory.
Authors: V Puetz; G Gahn; U Becker; D Mucha; A Mueller; N U Weir; B Wiedemann; R von Kummer Journal: AJNR Am J Neuroradiol Date: 2007-11-07 Impact factor: 3.825
Authors: Marc I Chimowitz; Michael J Lynn; Harriet Howlett-Smith; Barney J Stern; Vicki S Hertzberg; Michael R Frankel; Steven R Levine; Seemant Chaturvedi; Scott E Kasner; Curtis G Benesch; Cathy A Sila; Tudor G Jovin; Jose G Romano Journal: N Engl J Med Date: 2005-03-31 Impact factor: 91.245
Authors: David Fiorella; Michael M Chow; Michael Anderson; Henry Woo; Peter A Rasmussen; Thomas J Masaryk Journal: Neurosurgery Date: 2007-08 Impact factor: 4.654
Authors: A S Turk; E I Levy; F C Albuquerque; G L Pride; H Woo; B G Welch; D B Niemann; P D Purdy; B Aagaard-Kienitz; P A Rasmussen; L N Hopkins; T J Masaryk; C G McDougall; D Fiorella Journal: AJNR Am J Neuroradiol Date: 2007-11-07 Impact factor: 3.825
Authors: Mikael Mazighi; Julien Labreuche; Fernando Gongora-Rivera; Charles Duyckaerts; Jean-Jacques Hauw; Pierre Amarenco Journal: Stroke Date: 2008-02-28 Impact factor: 7.914
Authors: Brendan Steinfort; Perry P Ng; Kenneth Faulder; Timothy Harrington; Verity Grinnell; William Sorby; Michael K Morgan Journal: J Neurosurg Date: 2007-02 Impact factor: 5.115
Authors: Z Vajda; T Güthe; M Aguilar Perez; A Heuschmid; E Schmid; H Bäzner; H Henkes Journal: AJNR Am J Neuroradiol Date: 2011-09-01 Impact factor: 3.825
Authors: Wiebke Kurre; Friedhelm Brassel; Roland Brüning; Jan Buhk; Bernd Eckert; Susanna Horner; Michael Knauth; Thomas Liebig; Jana Maskova; Dirk Mucha; Vojtech Sychra; Matthias Sitzer; Michael Sonnberger; Marc Tietke; Johannes Trenkler; Bernd Turowski; Joachim Berkefeld Journal: Neuroradiology Date: 2011-01-11 Impact factor: 2.804
Authors: Sebastian Fischer; Zsolt Vajda; Marta Aguilar Perez; Elisabeth Schmid; Nikolai Hopf; Hansjörg Bäzner; Hans Henkes Journal: Neuroradiology Date: 2011-09-01 Impact factor: 2.804